LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 74 of 273
+CIND - Indicator Control
where:
<descr>
- indicator names as follows (along with their
<ind>
ranges)
“battchg” - battery charge level
<ind>
- battery charge level indicator range
0..5
99 - not measurable
“signal” - signal quality
<ind>
- signal quality indicator range
0..7
99 - not measurable
“service” - service availability
<ind>
- service availability indicator range
0 - not registered to any network
1 - registered
“sounder” - sounder activity
<ind>
- sounder activity indicator range
0 - there’s no any sound activity
1 - there’s some sound activity
“message” - message received
<ind>
- message received indicator range
0 - there is no unread short message at memory locations
1 - unread short message at memory locations
“call” - call in progress
<ind>
- call in progress indicator range
0 - there’s no calls in progress
1 - at least a call has been established
“roam” - roaming
<ind>
- roaming indicator range
0 - registered to home network or not registered
1 - registered to other network
“smsfull” - a short message memory storage in the MT has become full (1), or
memory locations are available (0)
<ind>
- short message memory storage indicator range
0 - memory locations are available
1 - a short message memory storage in the MT has become full.
“rssi” - received signal (field) strength
<ind>
- received signal strength level indicator range
0 - signal strength ≤ (-112) dBm
1..4 - signal strength in 15 dBm steps
5 - signal strength ≥ (-51) dBm
99 - not measurable
Example
Next command causes all the indicators to be registered
AT+CIND=1,1,1,1,1,1,1,1,1
Next command causes all the indicators to be de-registered
AT+CIND=0,0,0,0,0,0,0,0,0
Next command to query the current value of all indicators
AT+CIND?
Summary of Contents for LE910-SKG