LE910-SKG AT commands reference guide
80437ST10619A Rev.1 – 2014-09-16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 69 of 273
+CPWD - Change Facility Password
Reference
3GPP TS 27.007
+CAOC - Advice Of Charge
AT+CAOC=
<mode>
Set command refers to the Advice of Charge supplementary services that enable
subscriber to get information about the cost of calls; the command also includes the
possibility to enable an unsolicited event reporting of the Current Call Meter
(CCM) information.
Parameter:
<mode>
0 - query CCM value
1 - disables unsolicited CCM reporting
2 - enables unsolicited CCM reporting
Note: the unsolicited result code enabled by parameter
<mode>
is in the format:
+CCCM: <ccm>
where:
<ccm>
- current call meter in home units, string type: three bytes of the CCM
value in hexadecimal format (e.g. “00001E” indicates decimal value 30)
Note: the unsolicited result code
+CCCM
is sent when the CCM value changes, but
not more than every 10 seconds.
AT+CAOC?
Read command reports the value of parameter
<mode>
in the format:
+CAOC: <mode>
AT+CAOC=?
Test command reports the supported values for
<mode>
parameter.
Reference
3GPP TS 27.007
Note
+CAOC
command returns an estimate of the cost of the current call only, produced
by the MS and based on the information provided by either AoCI or AOCC
supplementary services; it is not stored in the SIM.
+CPOL - Preferred Operator List
AT+CPOL=
[<index>][,<format>
[,<oper>[,<GSM_AcT
>,
<GSM_Compact_Ac
T>,
<UTRAN_AcT>,<E-
UTRAN_AcT>]]
Execution command writes an entry in the SIM list of preferred operators.
Parameters:
<index>
- integer type; the order number of operator in the SIM preferred operator
list
1..
n
<format>
2 - numeric
<
oper
> - string type
<GSM_AcT>
- GSM access technology
Summary of Contents for LE910-SKG