LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 1161 of 1904
2022-03-04
Not Subject to NDA
3.15.28.
AT#TEMPMON - Temperature Monitor
This command is used to retrieve internal temperature information of the module.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#TEMPMON=<mod>[,<urcMode>[,<action>[,<GPIO>]]]
Set command sets the behavior of the module internal temperature
monitor.
#TEMPMEAS: <level>,<value>
The temperature monitoring message parameters are described in the
Unsolicited fields section.
Parameters:
Name
Type
Default
Description
<mod>
integer
N/A
select the temperature monitoring
mode.
Values:
0 : sets the command parameters
1 : triggers the measurement of the module internal
temperature, reporting the result using the format
shown above
<urcMode>
integer
1
URC presentation mode
Values:
0 : disables the presentation of the temperature
monitoring URC.
Summary of Contents for LE910C series