LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 1163 of 1904
2022-03-04
Not Subject to NDA
-1 : Operating temperature lower bound.
0
: normal temperature.
1
: Operating temperature upper bound.
2
: Extreme temperature upper bound.
<value> integer actual temperature expressed in degrees Celsius.
AT#TEMPMON?
Read command reports the current parameter settings for the command
in the format:
#TEMPMON: <urcMode>,<action>[,<GPIO>]
AT#TEMPMON=?
Test command reports the supported range of values for parameters
<mod>, <urcMode>, <action>, and <GPIO>.
Thresholds levels are defined in #TEMPCFG command. See there for
detailed description on thermal mitigation configuration.
Last <GPIO> is saved in the NVM.
Thermal mitigation is disabled automatically when using laboratory
test SIM.