LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 1236 of 1904
2022-03-04
Not Subject to NDA
The checking if new data have
been received from serial port
is done with a granularity that
is directly related to #SCFG
<txTo> setting with a
maximum period of 1 sec.
Values:
0 : select "old" method: start transmission
timer only first time if new data are
received from the serial port
1 : select "new" method: restart
transmission timer when new data is
received from serial port
<abortConnAttempt> integer
0
enable the abort of an ongoing
connection attempt started by
#SD command and before the
reception of the CONNECT
message (in online mode) or
OK message (in command
mode).
Values automatically saved in
NVM.
Values:
0 : not possible to interrupt connection
attempt
1 : it is possible to interrupt the connection
attempt (<connTo> set by #SCFG or DNS
resolution running if required) and give
back control to AT interface by reception
of a character. As soon as the control
given to the AT interface, the ERROR
message will be received on the interface
itself.
<unused_B>
integer
-
reserved for future use
Summary of Contents for LE910C series