<rst>
integer
0
reset flag
Values:
0 : do not reset the ME before setting it to <fun>
functionality level.
1 : reset the ME before setting it to <fun> functionality level,
this option works only with <fun> =1, with other it will
return an error
Additional info:
<fun>=0
minimum functionality, NON-CYCLIC SLEEP mode: the AT interface
is not accessible. Consequently, once you have set <fun> level 0, do
not send further characters. Otherwise these characters remain in
the input buffer and may delay the output of an unsolicited result
code. The first wake-up event stops power saving and takes the ME
back to full functionality level <fun>=1.
Special modes, you can only see them only through the read
command and you can't set those mode:
7 - Offline mode
8 - FTM
AT+CFUN=2 is same with <fun> 1 but the disable TX function is not
supported.
Issuing AT+CFUN=4[,0] causes the module to perform either a
network deregistration and a SIM deactivation.