LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 151 of 1904
2022-03-04
Not Subject to NDA
AT+CIND?
Read command returns the current value of ME indicators, in the format:
+CIND: <ind>,<ind>,...<ind>
the order of the values <ind>s is the same as that in which the
associated indicators appear from test command AT+CIND=?.
AT+CIND=?
Test command returns pairs, where string value <descr> is a description
(max. 16 chars) of the indicator and compound value is the supported
values for the indicator, in the format:
+CIND: (<descr>, (list of supported <ind>s)),(<descr>, (list of supported
<ind>s)),... (<descr>, (list of supported <ind>s))
Additional info:
Test command response parameters
Name
Type
Default
Description
<descr>
string
N/A
indicator names as
follows (along with
their <ind> ranges).
Values:
"battchg"
: battery charge level; indicator
<ind> in the range 0...5(bar
levels), or 99 (not measurable)
"signal"
: signal quality; indicator <ind> in
the range 0...7(bar levels), or 99
(not measurable); same as bit
Summary of Contents for LE910C series