<param> integer
0
When <paramType>=1, <param> is
the battery voltage threshold to
monitor.
Value:
0÷500 : 1 unit is 10 mV.
<param> integer
0
When <paramType>=2, <param> is
the time interval starting from the
instant in which the voltage battery
goes below the threshold specified
with <paramType>=1. When the
interval is elapsed and the voltage
battery is below the threshold, the
#EVMONI executes the AT command
configured with <paramType>=0.
Value:
0÷255 : seconds
<label>=DTR, DTR monitoring.
<paramType> can assume values in the range 0 - 2.
Name
Type
Default
Description
<param> integer
0
When <paramType>=1, <param> is
the DTR status to monitor.
Values:
0 : Low
1 : High
<param> integer
0
When <paramType>=2, <param> is
the time interval starting when DTR
status has the value specified with
<paramType>=1. When the interval
Summary of Contents for LE910C series