LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 1810 of 1904
2022-03-04
Not Subject to NDA
<user_property_name> string
-
User property name, string
type. Valid and mandatory
if the <identifier> set to 38
<user_property_value> string
-
User property value, string
type. Valid and mandatory
if the <identifier> set to 38
This command only valid if the MQTT version of the corresponding
<instance_number> is set to v5.0
AT#MQSUPP?
Read command reports the currently selected parameters in the format:
#MQSUPP: <instance_number>,<identifier>,<value>
<instance_number>,<identifier>,<value>
...
<instance_number>,<identifier>,<value>
AT#MQSUPP=?
Test command reports the supported range of values for parameters
#MQSUPP: (1-max_instance),(11,38),,,
Set command
AT#MQSUPP=1,11,1
OK
Test command
AT#MQSUPP=?
#MQSUPP: (1-2),(11,38),,,
OK