LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 1819 of 1904
2022-03-04
Not Subject to NDA
38 : 0x26, User Property. <value>
mapping to this identifier stands for
the user property index, which can be
only set to 1 currently
<value>
mixed
-
Value of the property
identifier
<user_property_name> string
-
User property name, string
type. Valid and mandatory
if the <identifier> set to 38
<user_property_value> string
-
User property value, string
type. Valid and mandatory
if the <identifier> set to 38
This command only valid if the MQTT version of the corresponding
<instance_number> is set to v5.0
AT#MQDIPP?
Read command reports the currently selected parameters in the format:
#MQDIPP: <instance_number>,<identifier>,<value>
<instance_number>,<identifier>,<value>
...
<instance_number>,<identifier>,<value>
AT#MQDIPP=?
Test command reports the supported range of values for parameters
#MQDIPP: (1-max_instance),(17,28,31,38),,