3.2.3.3.
ATS2 - Escape Character
The command manages the ASCII character used as escape character.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Specific profile
No
-
2
ATS2=<char>
Set command sets the ASCII character to be used as escape character.
Parameter:
Name
Type
Default
Description
<char> integer
43
escape character decimal ASCII
Value:
43 : factory default value is '+'
The escape sequence consists of three escape characters
preceded and followed by n ms of idle (see S12 to set n).
This command only supports 43 for <char> parameter.
ATS2?
Read command returns the current value of S2 parameter.
The format of the numbers in output is always 3 digits, left-filled
with 0s.