3.4.58.
AT+COPS - Operator Selection
The command selects a network operator and registers the module.
3GPP TS 27.007
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Auto
Yes
-
2
AT+COPS=[<mode>[,<format>[,<oper>[,<act>]]]]
The set command attempts to select a network operator and registers the
module on the just chosen operator; the selection can be automatic or
manual.
Parameters:
Name
Type
Default
Description
<mode> integer
0
defines the operator selection: automatic
or manual.
Values:
0 : automatic selection, the parameter <oper> is ignored
1 : manual selection, the parameter <oper> must be
present
2 : deregister from network. The module is unregistered
until a +COPS with <mode>=0, 1 or 4 is issued
3 : set only <format> parameter, the parameter <oper>
is ignored
4 : manual/automatic, <oper> parameter must be
present. If manual selection fails, the module will
tray automatic mode (<mode>=0)