LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 685 of 1904
2022-03-04
Not Subject to NDA
Time & Alarm
3.7.1.
AT+CCLK - Clock Management
The command is related to real time clock management.
3GPP TS 27.007
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT+CCLK=<time>
Set command sets the real-time clock of the module.
Parameter:
Name
Type
Default
Description
<time>
string
N/A
Current time as quoted
string in the format:
"yy/MM/dd,hh:mm:ss±zz"
Values:
yy
: year (two last digits are mandatory), range is 00..99
MM : month (two digits are mandatory), range is 01..12
dd
: day (two digits are mandatory) The range for dd(day)
depends either on the month and on the year it
refers to. Available ranges are: (01..28) (01..29)
(01..30) (01..31). Trying to enter an out of range value
will raise an ERROR message.
hh
: hour (two digits are mandatory), range is 00..23
mm : minute (two digits are mandatory), range is 00..59