LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 957 of 1904
2022-03-04
Not Subject to NDA
3.11.6.
AT#STIME - Set SIM Toolkit timeout value
This command sets the timeout value for STK timeout test of GCF/PTCRB.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT#STIME=[<mode>]
Set command sets a unit of STK timeout value.
Parameter:
Name
Type
Default
Description
<mode>
integer
0
a unit of STK timeout value
Values:
0 : in minute
1 : in second
AT#STIME?
Read command returns the current <mode>.
AT#STIME=?
Test command returns the supported range of values for parameter
<mode>.
AT#STIA command is not set to a second unit. When you test "No response
from user" and "timeout" of STK test, you must change to a second unit to
timeout value of STK.
Summary of Contents for LE910C series