LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 1061 of 1904
2022-03-04
Not Subject to NDA
eCall
3.13.1.
AT+CECALL - Initiate eCall
The command is to trigger an eCall to the network.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT+CECALL=<eCallType>
Set command is used to trigger an eCall to the network. Based on the
configuration selected, it can be used to either trigger a test call, a
reconfiguration call, a manually initiated call or an automatically initiated
call.
Parameter:
Name
Type
Default
Description
<eCallType> integer
0
eCall type that must be initiated
Values:
0 : test call
1 : reconfiguration call
2 : manually initiated eCall
3 : automatically initiated eCall
Additional info:
The sending of a MSD is pointed out with an unsolicited message
through AT interface that can report the HL-ACK data bits or an
error code with the format:
#ECALLEV: <prim>,<data>
Summary of Contents for LE910C series