LE910Cx AT Commands Reference Guide
80502ST10950A Rev. 14
Page 1081 of 1904
2022-03-04
Not Subject to NDA
3.14.2.
AT#ENHRST - Periodic Reset
Enable or Disable the one shot or periodic unit reset
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Auto
No
-
2
AT#ENHRST=<mode>[,<delay>]
Set commands enables/disables the unit reset after the specified <delay>
in minutes
Parameters:
Name
Type
Default
Description
<mode> integer
0
Enable\Disable mode
Values:
0 : disables the unit reset
1 : enables the unit reset only one time (one shot reset)
2 : enables periodically unit reset
<delay> integer
-
time interval in minutes after that the unit
reboots; numeric value in minutes
The settings are saved automatically in NVM only if old or new
<mode> value is 2, i.e. unit set in periodic reset mode. Therefore,
any change from 0 to 1 or conversely is not stored in NVM.
The command AT#ENHRST=1,0 causes the immediate module
reboot. If it follows an AT command that stores some parameters
in NVM, it is strongly recommended to insert a delay of at least 5
sec before issuing it, to permit the complete NVM storing process.
Summary of Contents for LE910C series