SE867-AGPS User Guide
1VV0300860 Rev. 3 - 2010-05-10
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved
page 50 of 69
an be switched on or off by following command:
$PUNV,CONFIG,SBAS,
Status
*cc
or
,SET,S
S,
Status
*
The SBAS functionality c
$PUNV
BA
cc
Name
Format
Valid values
Default value
Description
Status String
ON, OFF
ON
SBAS status:
ON – SBAS is switched on,
OFF- SBAS is switched off.
In case of successful execution of
$PUNV,CONFIG,SBAS,
Status
*cc
command, the receiver sends confirmation in a following form:
$PUNV,CFG_S,11*53
In case of failure of execution of GETCONFIG, CONFIG or SET command the receiver
sends the ERR reply message. Please see the ERR section for details (10.1.2.17).
10.1.3.6.
2D Configuration
The 2D configuration is used to configure SE867-AGPS 2D fix control.
The current 2D fix control configuration can be read in the system with the following
command:
$PUNV,GETCONFIG,11*48
The answer is as follows:
$PUNV,CFG_R,11,
x,2DControlReacquisition_2DControlAll_2DControlCold,AltAidin
gVal,StartFallbackTimeout2D,ReacqFallbackTimeout2D,x,x,x,x,x,x,x
*cc
The SE867-AGPS 2D control can be changed by the following command
$PUNV,CONFIG,2D,
2DControlReacquisition_2DControlAll_2DControlCold,AltAiding
Val,StartFallbackTimeout2D,ReacqFallbackTimeout2D
*cc