PROGRAMMING SOFTWARE: 

The  latest  version  of  the  programming  software  is  available  on  the 
manufacturer’s website. 

Connecting via USB 

-  Launch the 

Gate Control

 programming software. 

-  Power  up  the  device  and  then  connect  it  to  the  computer  using  a  USB  A-B 

cable. 

-  Select the 

USB 

 

option in the 

Connection type

 menu. 

-  Enter the 

USB connection password

 (default password: 

1234

), then click on 

the 

Connect 

 

button. 

-  In  order  to  configure  the  settings,  first  you  need  to  read  the  actual  settings 

stored in the device. For this, click on any menu item in the 

Device settings

 

group and read the settings by clicking on the 

Read settings

 

 

button. 

-  Configure the settings as needed, and then write the changed settings into the 

device by clicking on the 

Write settings

 

 

button. 

APN, PIN code, and Cloud: 

In order to access the device remotely over the Internet, the 

APN

 needs to be 

configured in the 

SIM settings

 section in the 

General

 device settings menu. 

If you want to lock the SIM card with a PIN code, then enter the PIN code of the 
SIM card in the 

SIM settings

 section and enable PIN code request on the SIM 

card. 

Remote access works through cloud service. In case of using a SIM card that 
uses  a  private  APN,  accessing  the  cloud  server  IP  address  in  the  given  APN 
must  be  specifically  enabled  at  the  mobile  service  provider.  The  cloud 
availabilities are the following: 

Server address:

 54.75.242.103   

Server port:

 2016 

 

 

Summary of Contents for BASE 1000

Page 1: ...closing is possible only from authorized phone numbers registered in the device or from any phone number according to the configuration if there are users registered with phone numbers in the user lis...

Page 2: ...card 4 If you want to lock the SIM card with a PIN code you will have to provide the PIN code in the device settings Otherwise disable PIN code request on the SIM card 5 Remove the SIM card bay cover...

Page 3: ...rs upon triggering the inputs Outputs and control modes The outputs provide normally open NO dry contacts as the default state and closed contacts when controlled except for control mode No 3 where ou...

Page 4: ...call only opens the gate Closing should be done automatically by the gate automation control board Control mode 3 For single gate automations that require triggers for opening and closing on the same...

Page 5: ...call Control mode 5 For single gate automations that require triggers for opening and closing on different inputs Opening and then closing by separate calls Both outputs are normally open NO The open...

Page 6: ...on the Read settings button Configure the settings as needed and then write the changed settings into the device by clicking on the Write settings button APN PIN code and Cloud In order to access the...

Page 7: ...new button to configure a password for remote access Select the User from the drop down menu and enter the Password that you want to use when signing in for remote programming and then click on the OK...

Page 8: ...ole S super admin A Admin U user ENTRY PERIOD replace this with your entry permission N 0 24 L only in the configured entry period GATE replace this with your output control permission 1 OUT1 2 OUT2 B...

Page 9: ...onnecting to the cloud Enter the Super admin or Admin User name and the remote access Password configured for that Send the request command for connecting to the cloud CONNECT by SMS to the phone numb...

Page 10: ...losing pulses A B or X Z the interval for keeping the gate locked in open state Y and the delay for intervention in the photocell loop W depending on the control mode chosen Configuring the entry peri...

Page 11: ...ncy bands 800 850 900 1900 2100 MHz UMTS 850 900 1800 1900 MHz GSM The 4G modem can use the following frequency bands 900 1800 MHz GSM EDGE B1 B8 WCDMA B1 B3 B7 B8 B20 B28A LTE The 4GA modem can use t...

Page 12: ...The device operates safely and properly only with a power supply which meets even the maximal requirements specified in the user s manual You can find the exact data in the user s manual and on the h...

Page 13: ...sz mok kezdem nyezhetik vagy b rmilyen telefonsz m a be ll t snak megfelel en ha vannak r gz tve felhaszn l k telefonsz mmal a modul felhaszn l list j ban akkor csak azokr l a telefonsz mokr l vez rel...

Page 14: ...t a modul be ll t saiban Ellenkez esetben tiltsa le a k rty n a PIN k d k r st 5 T vol tsa el a modul ny l s nak fedel t s helyezze be a SIM k rty t 6 Ellen rizze a telep t si k rnyezetet gyenge t rer...

Page 15: ...ntaktust vez rl skor pedig z r kontaktust szolg ltatnak kiv ve a 3 as vez rl si m d eset ben ahol az OUT2 kimenet alaphelyzetben z rt NC A rel kontaktusok maxim lis terhelhet s ge 1A 24V AC DC Az eszk...

Page 16: ...thez Egy vez rl h v s csak kapunyit st v gez A z r st a kapuvez rl nek automatikusan kell v geznie 3 vez rl si m d Olyan egykapus kapuautoma tik khoz amelyek a nyit s s a z r s vez rl kontaktust ugyan...

Page 17: ...sa 5 vez rl si m d Olyan egykapus kapuautomati k khoz amelyek a nyit si s z r si parancsot elt r bemeneteken v rj k Nyit s s z r s k l n h v ssal Mindk t kimenet alaphelyzetben nyitott NO A nyit si i...

Page 18: ...oportban s olvassa ki a be ll t sokat a Be ll t sok olvas sa gomb seg ts g vel M dos tsa a be ll t sokat ig ny szerint majd rja be a m dos tott be ll t sokat a modulba a Be ll t sok r sa gomb seg ts g...

Page 19: ...mbra a t vhozz f r si jelsz be ll t s hoz V lassza ki a Felhaszn l t a leg rd l men b l adja meg a Jelsz t amelyet a t vprogramoz shoz t rt n bejelentkez shez szeretne haszn lni majd kattintson a Rend...

Page 20: ...zerepk r vel S szuperadminisztr tor A adminisztr tor U felhaszn l BEL P SI ID SZAK helyettes tse az n enged lyezett bel p si id szak val N 0 24 L csak a be ll tott id szakban vez relhet KAPU helyettes...

Page 21: ...Adja meg a szuperadminisztr tori vagy adminisztr tori Felhaszn l nevet s az ehhez be ll tott t vhozz f r si Jelsz t K ldje el a Gate Control BASE modulba helyezett SIM k rtya telefonsz m ra SMS ben a...

Page 22: ...nyit si s z r si impulzusok param terei A B illetve X Z a kapu nyitva tart s nak id tartama Y valamint a fotocella rz kel k r megszak t s nak k sleltet se W Enged lyezett bel p si id szak be ll t sa...

Page 23: ...50 900 1800 1900 MHz GSM A 4G modem az al bbi frekvencias vokat haszn lhatja 900 1800 MHz GSM EDGE B1 B8 WCDMA B1 B3 B7 B8 B20 B28A LTE A 4GA modem az al bbi frekvencias vokat haszn lhatja B2 B4 B5 WC...

Page 24: ...gezheti BIZTOS TSON MEGFELEL RAMFORR ST az eszk znek Az eszk z csak olyan t pegys g haszn lata eset n m k dik biztons gosan s megfelel en amely az eszk z k zik nyv ben megadott k vetelm nyek maxim li...

Page 25: ...erten Rufnummern oder von irgendwelcher der Einstellung entsprechenden Rufnummer ausgel st werden falls Anwender mit Telefonnummern in der Anwenderliste des Moduls gespeichert worden sind kann die Ste...

Page 26: ...IN Code unter den Moduleinstellungen angeben Deaktivieren Sie ansonsten die PIN Code Anforderung auf der SIM Karte 5 Entfernen Sie den ffnungsdeckel des Moduls und legen Sie die SIM Karte ein 6 berpr...

Page 27: ...ei der Steuerung einen Schlie kontakt ausgenommen im Falle von Steuerungsmodus 3 in der der Ausgang OUT2 normalerweise geschlossen NC ist Die maximale Belastbarkeit der Relaiskontakte betr gt 1A 24V A...

Page 28: ...Ein Steuerungsbefehl t tigt nur Tor ffnung Die Torschlie ung muss vom Torsteuerungssystem automatisch durchgef hrt werden Steuerungsmodus 3 Zu Ein Tor Torautomatiken die die Steuerkontakte f r ffnen...

Page 29: ...Tor Torautomatiken die die Steuerungsbefehle f r ffnen und Schlie en an unterschiedlichen Eing ngen erwarten ffnen und Schlie en per getrennten Anruf Beide Ausg nge sind normalerweise ge ffnet NO Der...

Page 30: ...ellungen mithilfe der Taste Einstellungen lesen aus ndern Sie die Einstellungen nach Wunsch dann schreiben Sie die ge nderten Einstellungen mithilfe der Taste Einstellungen schreiben ins Modul ein APN...

Page 31: ...chtigungen nach Wunsch und klicken Sie schlie lich die Taste OK an und schreiben Sie den Anwender mithilfe der Taste Anwender schreiben ins Modul ein Schalten Sie auf den Men punkt Fernzugriff um dann...

Page 32: ...N und mit Ihrer Telefonnummer registriert SUPERADMIN NAME mit diesem Befehl werden Sie mit dem Namen den Sie anstelle von NAME einschreiben und mit Ihrer Telefonnummer im Modul registriert n TELNUMMER...

Page 33: ...Cloud Falls Sie die Modul Erreichbarkeiten im Men Modulregister vorher schon gespeichert haben w hlen Sie dasjenige Modul das Sie erreichen m chten aus dem Drop down Men Modulname aus Geben Sie ander...

Page 34: ...gangsereignisse konfiguriert werden Einstellung der Ausg nge Der Steuerungsmodus der Ausg nge kann im Men Ausg nge konfiguriert werden Bei der Auswahl des Steuerungsmodus k nnen die Parameter der ffnu...

Page 35: ...requenzb nder benutzen 900 1800 MHz GSM EDGE B1 B8 WCDMA B1 B3 B7 B8 B20 B28A LTE Das 4G Modem kann folgende Frequenzb nder benutzen B2 B4 B5 WCDMA B2 B4 B5 B12 B13 LTE BENUTZEN SIE das Ger t NICHT in...

Page 36: ...ORGEN SIE das Ger t MIT EINER ANGEMESSENEN STROMQUELLE Das Ger t funktioniert sicher und ordnungsgem nur bei der Nutzung eines solchen Netzteils das auch die maximalen Werte der in dem Handbuch des Ge...

Reviews: