7 Technical details 

7.1 Technical specification 

Supply voltage: 

 

9-30 VDC 

Nominal current consumption:   

110mA @ 12VDC, 60mA @ 24VDC 

Maximum current consumption: 

400mA @ 12VDC, 200mA @ 24VDC 

Operating temperature: 

 

-20ºC - +70ºC 

Transmission frequency: 

 

GSM 900/1800 MHz, 850/1900 MHz 

GSM phone type: 

 

Simcom SIM900 

Dimensions: 

 

100 x 70 x 19mm 

Weight: 

 

80g (packed: 100g) 

7.2  Generated phone line specification 

Line voltage: 

48 V 

Line current:                            20 mA 
Line impedance: 

600 Ohm 

Ring voltage: 

±72V (25 Hz) 

Tone: 400 

Hz 

7.3  Contents of the package 

  ECOLINE SIA IP module 

  GSM 900/1800 MHz antenna 

 Plastic spacer 

 User manual 

 USB cable 

 Warranty card 

 

Summary of Contents for ecoLINE SIA IP

Page 1: ...ecoLINE SIA IP Adapter INSTALLATION AND APPLICATION MANUAL for module version v2 25 and higher Rev 1 5 21 06 2012...

Page 2: ...for backup GSM call 5 3 1 6 Modification of the settings by SMS 5 3 1 7 Incoming SMS message forwarding 5 3 2 Configuring by SMS commands 6 4 Volume adjusting application 8 5 Module status 9 5 1 LED s...

Page 3: ...P protocol based on ANSI SIA DC 09 2007 standard No need for a central server only an IP receiver with internet connection is necessary The list of the supported receivers is available on www tell hu...

Page 4: ...e alarm panel then it converts the received events to IP based format and transfers to the configured addresses To check the continuous connections it is possible to enable test reports Test reports c...

Page 5: ...panel In case of using more than one partition user ID then enter the first partition s user ID The module sends the GPRS IP test reports using this user ID The length of the SIA user ID can be minim...

Page 6: ...he IP addresses substitute X with the ordinal number of the IP address to be set or modified PORTX port number Setting the port numbers substitute X with the ordinal number of the IP address port numb...

Page 7: ...do not enter any data after the equality sign This can be applied for all data setting commands in the table above Example PH2 deletes the second phone number assigned to the second IP address IP3 del...

Page 8: ...oftware Start the Volsetter exe application Connect the module to USB The software connects to the module automatically then Read and Set buttons become available Read the actual settings from the mod...

Page 9: ...rsion of the hardware Firmware version version of the firmware System timer Date time internal clock of the connected module Uptime elapsed time since the last module restart GSM status GSM signal cur...

Page 10: ...ces In case of occasionally occurring signal strength problems or and wave interference fading use another directed type of antenna or find a more suitable place for the module 6 2 Putting into operat...

Page 11: ...0 C 70 C Transmission frequency GSM 900 1800 MHz 850 1900 MHz GSM phone type Simcom SIM900 Dimensions 100 x 70 x 19mm Weight 80g packed 100g 7 2 Generated phone line specification Line voltage 48 V Li...

Reviews: