9
5 Module status
5.1 LED signals
Green blinks slowly,
Red is not lit
GPRS OK
Green is continuously lit
IP reporting in progress
Green blinks fast
GSM reporting in progress
Red blinks 3 times
Reporting failed
Red is continuously lit
Trouble
5.2 Status
On the
“Status”
page the connected ecoLINE SIA IP Adapter’s state can be monitored
(version information, system timer, GSM status, GPRS network, communication, event
monitoring).
Available status information:
Version information:
- Type:
type of the module
- Hardware
version:
version of the hardware
- Firmware
version:
version of the firmware
System timer:
- Date/time:
internal clock of the connected module
- Uptime:
elapsed time since the last module restart
GSM status:
- GSM
signal:
current GSM signal strength
- Uptime:
elapsed time since the last GSM network connection
GPRS network:
- Module
IP:
the module’s actual IP address
- Uptime:
elapsed time since the last GPRS network connection
- Data
traffic:
data traffic since the last GPRS network connection
- Number of connections:
actual number of the IP connections
Communication:
- Line
status:
actual line state
- Dialed
number:
the last number dialed by the alarm control panel
- Protocol:
the last used protocol
Event monitoring:
list of the latest Contact ID events