background image

 

9

5 Module status 

5.1 LED signals 

 

Green blinks slowly, 
Red is not lit 

GPRS OK 

Green is continuously lit 

IP reporting in progress 

Green blinks fast 

GSM reporting in progress 

Red blinks 3 times  

Reporting failed 

Red is continuously lit 

Trouble 

 

5.2 Status 

On the 

“Status”

 page the connected ecoLINE SIA IP Adapter’s state can be monitored 

(version information, system timer, GSM status, GPRS network, communication, event 
monitoring). 
 
Available status information:  
 

 

Version information:

 

- Type: 

type of the module 

- Hardware 

version:

 version of the hardware 

- Firmware 

version:

 version of the firmware 

 

 

System timer: 
- Date/time: 

internal clock of the connected module

 

- Uptime: 

elapsed time since the last module restart

 

 

 

GSM status: 
- GSM 

signal: 

current GSM signal strength 

- Uptime: 

elapsed time since the last GSM network connection

 

 

 

GPRS network: 
- Module 

IP: 

the module’s actual IP address 

- Uptime: 

elapsed time since the last GPRS network connection 

- Data 

traffic: 

data traffic since the last GPRS network connection

 

-  Number of connections: 

actual number of the IP connections 

 

 

Communication: 
- Line 

status: 

actual line state 

 

- Dialed 

number: 

the last number dialed by the alarm control panel

 

- Protocol:

 the last used protocol

 

 

 

Event monitoring:

 list of the latest Contact ID events

 

Summary of Contents for ecoLINE SIA IP

Page 1: ...ecoLINE SIA IP Adapter INSTALLATION AND APPLICATION MANUAL for module version v2 25 and higher Rev 1 5 21 06 2012...

Page 2: ...for backup GSM call 5 3 1 6 Modification of the settings by SMS 5 3 1 7 Incoming SMS message forwarding 5 3 2 Configuring by SMS commands 6 4 Volume adjusting application 8 5 Module status 9 5 1 LED s...

Page 3: ...P protocol based on ANSI SIA DC 09 2007 standard No need for a central server only an IP receiver with internet connection is necessary The list of the supported receivers is available on www tell hu...

Page 4: ...e alarm panel then it converts the received events to IP based format and transfers to the configured addresses To check the continuous connections it is possible to enable test reports Test reports c...

Page 5: ...panel In case of using more than one partition user ID then enter the first partition s user ID The module sends the GPRS IP test reports using this user ID The length of the SIA user ID can be minim...

Page 6: ...he IP addresses substitute X with the ordinal number of the IP address to be set or modified PORTX port number Setting the port numbers substitute X with the ordinal number of the IP address port numb...

Page 7: ...do not enter any data after the equality sign This can be applied for all data setting commands in the table above Example PH2 deletes the second phone number assigned to the second IP address IP3 del...

Page 8: ...oftware Start the Volsetter exe application Connect the module to USB The software connects to the module automatically then Read and Set buttons become available Read the actual settings from the mod...

Page 9: ...rsion of the hardware Firmware version version of the firmware System timer Date time internal clock of the connected module Uptime elapsed time since the last module restart GSM status GSM signal cur...

Page 10: ...ces In case of occasionally occurring signal strength problems or and wave interference fading use another directed type of antenna or find a more suitable place for the module 6 2 Putting into operat...

Page 11: ...0 C 70 C Transmission frequency GSM 900 1800 MHz 850 1900 MHz GSM phone type Simcom SIM900 Dimensions 100 x 70 x 19mm Weight 80g packed 100g 7 2 Generated phone line specification Line voltage 48 V Li...