FOR MODULE VERSION V1.0 AND NEWER 

 

Summary of Contents for PAGER7

Page 1: ...FOR MODULE VERSION V1 0 AND NEWER ...

Page 2: ...ntrollable by event Configurable event action pairs Configurable active dashboard with active tiles at will Configurable Contact IDs for every input and custom event E mail sending SMS sending and voice call functionality Multiplatform application Windows Linux MacOS Cameras can be assigned with zones to display and record their images in case of an alarm Independent alarm function Support of TELL...

Page 3: ...2 2 3 Connecting outputs 7 2 3 Powering the module 8 2 4 Wiring 8 2 4 1 Wiring of Pager 7 Z4 8 2 4 2 Wiring of Pager 7 Z6 9 2 5 SIM card related information 9 2 5 1 Selecting services 9 2 5 2 SIM card holder 10 2 6 Connecting the antenna 10 2 7 Installation environment 10 2 8 Putting into operation 11 2 9 LED signals 11 3 The Pager 7 programming software 11 3 1 User levels 11 3 2 Logging into the ...

Page 4: ...nu point 25 4 5 3 Emails menu point 25 4 5 4 Sounds menu point 25 4 5 5 Push notifications 26 4 6 Alarm settings menu point 26 4 7 Signalling to monitoring station 26 4 7 1 Surveillance settings menu point 27 4 7 2 Surveillance schemas 28 4 8 Event settings 29 4 8 1 Events 30 4 8 2 Actions 33 4 8 3 Presets 35 4 9 Log configuration and debug 36 4 9 1 Log menu point 36 4 9 2 Configuration menu point...

Page 5: ... from a power supply provided with a backup battery and there is no other electrical load on the battery when charging fails e g in case of a power cut while the battery discharges the module turns off automatically at 8 3V voltage level Thereafter if the battery is in good condition it can regenerate and can reach the terminal voltage of 11 6V where the module turns back on then the battery may d...

Page 6: ... of their clear and explicit consent by providing voluntarily the personal data in a direct or indirect way The purpose of personal data processing is to ensure access to the system and thus to provide permission of use for users who wish to use the system The system stores the personal data in the device s memory The personal data are not accessible for third party only for the system operator in...

Page 7: ...tion 500mA 12V DC 250mA 24V DC Maximum relay output load 1A 24V AC DC GSM phone type QUECTEL UG95 GSM band 900 1800MHz UMTS band 900 2100MHz Dimensions 84x72x32 mm Weight 200 g Operation temperature 20 C 70 C 1 6 Contents of the package Pager 7 terminal connector GSM 900 1800MHz antenna User manual Warranty card ...

Page 8: ...e considered between the selected input eg IN1 and the negative V terminal of the supply voltage and need to be connected accordingly For the proper operation of inputs it is essential to specify the type of inputs NO or NC and enable them in the programming software These settings are explained in detail in section 4 2 of this manual 2 2 2 Connecting temperature sensor Each input of Pager 7 is ca...

Page 9: ...t be assured otherwise auxiliary power supply 230V AC 12V DC 1A can be ordered from the manufacturer 2 4 Wiring 2 4 1 Wiring of Pager 7 Z4 System terminal inputs and outputs V Supply voltage 9 30V DC min 500 mA V Supply voltage negative polarity IN1 1 contact input IN2 2 contact input IN3 3 contact input IN4 4 contact input OUT1 1 normally open relay contact OUT2 2 normally open relay contact In o...

Page 10: ...es of Pager 7 you d like to use in practice Several features of Pager 7 require having a mobile internet connection A few of these features are remote programming remote firmware update reporting to a monitoring station and certain notification options like e mail sending In case the SIM card has no mobile internet service the module can be programmed only through USB connection and it can send on...

Page 11: ...ule Connect the GSM antenna to the FME M socket The module comes with an antenna which provides good transmission under normal reception circumstances In case of experiencing signal strength problems or and wave interference fading use another directed type of antenna or find a more suitable mounting place for the antenna 2 7 Installation environment Before installing the module verify the GSM sig...

Page 12: ...irmware update is in progress 3 The Pager 7 programming software The latest version of the programming software is downloadable from the manufacturer s website http tell hu en products gprs communicators pager 7 Launch the installer and follow the instructions of Setup Wizard until the installation is complete 3 1 User levels Pager 7 has 2 user levels with different rights The admin has access to ...

Page 13: ...r it is enough for configuring the device The GSM network and the Internet access can only be assured if the proper power supply is connected The requirements of the power supply are described in detail in section 2 3 of this manual 3 3 Logging into the programming software through internet connection To remote programming Pager 7 mobile Internet connection is required and the module needs to be a...

Page 14: ...e left to the right The TELL logo brings back to the dashboard from anywhere The time and date are automatically synchronized from the GSM network If you want to manually synchronize them from the computer you can do so in the Module settings menu The signal strength in the header shows the module s actual GSM signal strength Above 60 the GSM signal strength is sufficient between 60 40 is low and ...

Page 15: ... notification address which is usually the installer s e mail address If there s an available update a notification link will appear in the notification email which link will start the firmware update The device sends an email notification about the success of the update Here you can specify the exact location of the device by selecting it on the map or entering the address The coordinates will be...

Page 16: ...The SIM card s APN can be set in the Access point settings section You can obtain the SIM card s APN from your SIM card provider In case the APN is not public you can also set the username and password in this section It is important that certain closed APNs do not allow to use the Internet freely but provide access only to selected IP addresses These closed APNs may block the use of Pager 7 featu...

Page 17: ... the automatic firmware update is also offered 4 1 2 Module status The page contains the most important information about the module The dynamic wiring diagram is located at the top of the page With the icons this provides an overview of the wires connected to the inputs even when the module is remotely accessed The Input states section lists the inputs with their icon name type and state This par...

Page 18: ...ally changing The Pager info section includes the device name the device type and the hardware ID for remote access Information on the firmware running on the device information on the SIM card the programming software s version and the GSM network related information are also in this section You can also find a QR code here that contains the hardware ID to help you log on from your mobile device ...

Page 19: ...plies to all inputs and serves to filter out the disturbances on the input Pager 7 considers only those contacts as events which are longer then the time specified here and the event actions are executed in this case only Output settings Here you can customize the 1 or 2 outputs depending on the device version A relay can be bistable or monostable The output configured as bistable has two stable s...

Page 20: ...le in case of a possible failure false signals coming from the zone can be eliminated by this setting Attention Zones need to be enabled in order to let the incoming contacts to generate event operations You can assign zones to partitions in the same field as well as setting up entry and exit delay times and 24h zones A 24h zone irrespectively of arming and disarming the partitions will always be ...

Page 21: ...e are available in the application with a single click from the alarm popup window At this time the zone violation could even be recorded which provides an opportunity for later play back 4 3 1 Camera settings New camera can be added by a click on Add camera button Here the name and the image URL of the camera picture planned to be used has to be entered The automatic update of the camera pictures...

Page 22: ...e dust bin icon 4 3 1 1 ONVIF camera link extraction In case you possess an ONVIF camera and you wish to find out the link of such a camera please follow our manual prepared for this aim which you can find at the bottom of the https tell hu en products gprs communicators pager 7 page among downloads 4 3 2 View cameras This menu point serves to look through and prepare records from the cameras adde...

Page 23: ...ctive dashboard can be reached anytime The entire surface is active which means that events and modifications are displayed real time on the compiled dashboard Some of the widgets placed on desktop are interactive It is possible to control relays by clicking on the widget or change the armed status of partitions 4 4 1 Adding widgets You can customize the desktop with help of the red edit button in...

Page 24: ...o be added has to be selected here The added widget is interactive it can be closed opened by a click Temperature sensor The temperature sensor required to be added has to be selected here Menu point A frequently used menu point can be selected here and added directly to the dashboard What we can add of 2x2 widgets Place This shows the place of the module as given in Module settings menu point Zon...

Page 25: ...icture The picture of an already added camera has to be selected here The update frequency of the camera can be configured in Camera settings menu point as it is written in point 4 3 1 4 5 Notification settings Pager 7 is able to send notifications in several ways about the events generated on the module There is an option for playing voice messages via calls sending SMS and emails To register the...

Page 26: ... this menu point you can enter the texts of e mails SMS and PUSH notifications which will be sent as notifications These schemes can be applied in Event settings menu point by SMS PUSH and e mail sending operations E mail text can be entered by giving the subject and the body of the e mail In case of SMS and PUSH notifications only the text should by typed in 16 text templates can be added by type...

Page 27: ... message sending to an event 4 6 Alarm settings menu point You can find the settings of the alarm event in this menu point which can be assigned to events as event action in Event settings menu point With the max alarm time you can set the time period under which the module stays in alarmed status from the supervention of alarm From alarmed status by the time the module will stay automatically bac...

Page 28: ...ntain numbers and A B C D E and F letters Secondary Client ID In case of the remote monitoring station requires a secondary Client ID needs to be given for client identification The minimal length of this identifier is 3 the maximal is 16 characters Encryption key If the remote monitoring station s server is using encrypted communication the required key has to be entered into this field The lengt...

Page 29: ... point 4 7 1 you have to create schemas in order to make the module able to execute Report action via net action and throughout Contact ID transmission Maximum 6 schemas can be created this way You can list maximum 6 servers in one schema These servers are in their basic status primary servers you can change their status to backup by ticking in the Server is backup option When you want to use the ...

Page 30: ... ticking in Add a reset event field Events and restore events form event pairs which can execute both activation and deactivation of an operation Event reset event example is zone detection and deleting zone detection In this case if a zone got violated the actions belonging to that event will prevail while if a zone got left according to the original event actions but contradictory actions will b...

Page 31: ...tore event pair of this event is API disconnect API disconnect Actions assigned to this event will be fulfilled by TELL cloud server connection break The restore event pair of this event is API connect Net connect Actions assigned to this event will be fulfilled by successful connection to the internet The restore event pair of this event is Net disconnect Net disconnect Actions assigned to this e...

Page 32: ...odified Actions assigned to this event will be fulfilled by changing module settings Scheduled action Actions assigned to this event will be fulfilled at a previously defined date Date can be entered by choosing the event Time changed Actions assigned to this event will be fulfilled by system time change Repeating action Actions assigned to this event will be repeated by the here defined frequency...

Page 33: ...illed by supply voltage decrease under a certain threshold limit Threshold limit can be entered by adding the event The restore event pair of this event is Voltage limit over Temperature sensor limit over Actions assigned to this event will be fulfilled by temperature raising above a certain threshold limit Temperature sensor and threshold limit can be chosen by adding the event The restore event ...

Page 34: ...event will be fulfilled by incoming impulse via impulse type inputs You can choose from among the impulse switch type inputs by adding the event Relay type events Relay close Actions assigned to this event will be fulfilled by relay tightening The relay can be chosen by adding the event The restore event pair of this event is Relay open Relay open Actions assigned to this event will be fulfilled b...

Page 35: ...ile You can add new phone numbers by clicking on the appropriate button when setting up the operation These numbers will be saved automatically and will be available later in Phone numbers menu Report action via net The module is able to send Contact ID code to one of the schemes added into Surveillance schemas You can enter the CID code by adding the event Relay close This action closes the selec...

Page 36: ...nt assigns the opposite action of the original action e g arming disarming In case the action doesn t have a restore action the Add a reset event option is not available Operation priority You can assign more actions to one event which will be fulfilled as per priority level The order of the same priority actions can be changed after the first adding and saving of the event The Immediate priority ...

Page 37: ... the event occurred its name two parameters and the fulfilment status of the actions In the event parameters you can find for example the input and relay IDs sensor data and information regarding module status With help of the arrows at the top of the chart you can switch among the pages jump to the beginning or the end of the log By typing in the number of the required page into the field between...

Page 38: ...loaded also from file this time you have to choose the appropriate configuration file from computer then click on Load button As an extra function you can modify the chosen configuration before loading by clicking on the edit icon Attention This function requires competence and high expertise 4 9 3 Debug information The chart containing the time category and parameters of debug information can be ...

Page 39: ...P Partition status query P has to be replaced with the number of partition e g 21 3RS Relay status setup R has to be replaced with the number of the relay wished to be controlled while S has to be replaced with 1 if you want to close 0 if you want to open the relay e g 321 3R Relay status query R has to be replaced with the number of the relay wanted to have a query on e g 31 DTMF command in case ...

Page 40: ...has to be replaced with 1 if you wish to close and 0 if you wish to open the relay e g R1 1 RX 1Z Relay status setting in monostabil mode X has to be replaced with the number of the relay wished to be controlled while Z has to be filled up with the time period in seconds in which the relay wished to stay closed e g R1 130 STATUS Status report query from module You will receive a similar list in a ...

Page 41: ...40 www tell hu Document version 1 0 31 08 2017 ...