www.telldus.com
Size (WxH): 180x190 mm
Features
• Self-programming with 67 million codes
• Remote control has 3 ch 1 group function
• Each outlet has 5 memory settings
• The remote control operates at a distance up to 30 metres (free line of sight)
• Green LED indicates ON/OFF and programming status
• The outlets are TellStick compatible.
WARNING!
• DO NOT OVERLOAD THE SYSTEM!
Do not use the system in humid places, e.g. in farms or basements and not in the vicinity of
inflammable liquids, solvents, colours or similar products.
Installation
1. Remove the small plastic tab from the battery in the remote control.
2. Connect the outlet to the mains.
3. Connect a lamp to the outlet. If there is a power switch on the connecting cable, make
sure it is switched on.
Programming an outlet
1. Install the outlet as explained under “Installation” above.
2. Keep the outlet programming button pressed for 3 seconds. The LED blinks slowly.
3. Press one of the ON buttons on the remote control within 10 seconds to link the
outlet to the button. (The programming mode is automatically disabled if no button is
pressed.)
4. The connected lamp blinks twice as confirmation.
Deprogramming a single code:
1. Keep the outlet programming button pressed for 3 seconds. The LED blinks slowly.
2. Press the corresponding OFF button on the remote control to remove the programmed
code. (The programming mode is automatically disabled after 10 seconds if no button
is pressed.)
3. The connected lamp blinks twice as confirmation.
4. To add a new code, repeat the programming procedure.
Deprogramming all codes
1. Keep the outlet programming button pressed for 5 seconds. The LED blinks rapidly.
2. Press the outlet programming button once more to remove all codes. (The programming
mode is automatically disabled after 10 seconds if the button is not pressed.)
3. The connected lamp blinks twice as confirmation.
4. To add a new code, repeat the programming procedure.
ON/OFF operation of a remote controlled outlet
1. Press the ON button on the remote control to switch on the power.
2. Press the OFF button to switch off the power.
3. Press the GROUP button to simultaneously switch all outlets ON or OFF.
4. ON/OFF switching is also possible by briefly pressing the outlet programming button.
The outlets have 5 memory settings
It is possible to programme the outlet to switch on separately or switch them on and off in
different combinations.
Example: Suppose that three outlets were programmed, where outlet 1 controls a table
lamp, outlet 2 controls a window lamp and outlet 3 controls a ceiling lamp.
• Outlets 1, 2 and 3 can be controlled separately using the ON and OFF buttons for each
channel on the remote control.
• Also two of the outlets (e.g. 1 and 3) can be programmed to a single button. It is then
possible to simultaneously control the table lamp and ceiling lamp.
Note: Do not program an ON/OFF outlet and a dimmer outlet to the same remote control button. It is
recommended to only program one dimmer outlet to each remote control button.
Troubleshooting
Connected lamp does not light:
1. If the outlet LED lights green:
• Check the light source.
• If there is a power switch on the connecting cable, make sure it is switched on.
2. If the outlet LED does not light green:
• Check the power supply to the outlet.
• Try pressing the ON button on the remote control once again.
3. If the problem persists:
• Check the battery in the remote control (transmitter).
• Check the programmed codes. It may be necessary to erase old codes and
reprogram the outlet.
Specifications
Remote control (transmitter):
Power supply:. . . . . . . . . . . . . . . . . . . . . . . . . 3V CR2032 battery (included)
Outlets (receiver):
Load on/off function (max.):. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000W
Operating range: . . . . . . . . . . . . . . . . . . . . . . . Up to 30m (free line of sight)
Protection class: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP20
Operating temperature (max.): . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40°C
Frequency: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433.92MHz
Power supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V~10A, 50Hz
312811 • User manual