background image

3.  IDs are excluded. 

LED 0.5s On, 0.5s Off 
(Enter auto inclusion) 

Association 

1.  The PAN11 is an always listening 

Z-Wave device, so associations may 
be added or removed by a controller 
at any time. 

Or    If your controller requires to have 

the PAN11 send a 'node information 
frame' or NIF for associations, then 
pressing the On/Off button three 
times within 2 seconds will cause 
the PAN11 to send its NIF. 

 

2.    There are only one group for the 

switch 

 

Including a node ID allocated by Z-Wave Controller means inclusion.    Excluding a node 
ID allocated by Z-Wave Controller means exclusion.

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

 

 

 
LED Indication

 

To distinguish what mode the switch is in, view from the LED for identification. 
 

State Type 

LED Indication 

Normal 

Under normal operation, toggle On/Off button between On and Off. 
When pressing On, LED lights up, whereas Off, LED is off. 

No node ID 

Under normal operation, when the Switch has not been allocated a 
node ID, the LED flashes on and off alternately at 2-second 
intervals. By pressing On/Off button, it will stop flashing 
temporarily.   

Learning 

When PAN11 is in learning mode, LED flashes on and off 
alternately and repeatedly at 0.5 second intervals.

 

Overload 

When overload state occurs, the Switch is disabled of which LED 
flashes on and off alternately at 0.2 second intervals. Overload 
state can be cleared by unplugging and reconnecting the Switch to 
the wall outlet.

 

 

Choosing a Suitable Location 
 

1.  Do not locate the Switch facing direct sunlight, humid or dusty place. 
2.  The suitable ambient temperature for the Switch is 0°C~40°C. 

3.  Do not locate the Switch where exists combustible substances or any source of 

heat, e.g. fires, radiators, boiler etc. 

4. 

After putting it into use, the body of Switch will become a little bit hot of which 
phenomenon is normal.

 

 
Installation 
 

1.  Plug this On/Off Switch into a wall outlet near the load to be controlled. 
 
2.  Plug the load into the Switch. Make sure the load to be controlled cannot exceed 

13A. 

 
3.  Press the button or switch on the load to the ON position. 
 
4.  To manually turn ON the Switch, press and release the On/Off button. The LED 

will turn ON, and the load plugged into the Switch will also turn ON. 

 
5.  To  manually  turn  OFF  the  Switch,  simply  press  and  release  the  On/Off  button. 

The LED will turn OFF and the load plugged into the Switch will also turn OFF. 

 
 

Programming 
 

1.    Basic Command Class / Binary Switch Command Class 

The  Switch  will  respond  to  BASIC  and  BINARY  commands  that  are  part  of  the 
Z-Wave system. 

 

1-1 BASIC_GET / BINARY_SWITCH_GET 

        Upon receipt of the following commands from a Z-Wave Controller, the Switch will 

report its On/Off state to the node asked. 

 

Basic Get Command: [Command Class Basic, Basic Get] 
Basic Report Command: 
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] 
Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]

 

 

Binary  Switch  Get  Command:[Command  Class  Switch  Binary,  Switch 
Binary Get]
 
Binary Switch Report Command: 
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value 
=0(0x00)]
 

Summary of Contents for PAN11-1B

Page 1: ...lashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be e...

Page 2: ...the Switch to the wall outlet Choosing a Suitable Location 1 Do not locate the Switch facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Switch is 0 C 40 C 3 Do no...

Page 3: ...ommand Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Class Switch Binary Switch Binary Report Value 0 0x00 2 1 2 Instant Power Consumption vary over 5 report When the power consu...

Page 4: ...ge V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report...

Page 5: ...eport its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days 3 3 Threshold of current for Load Caution This is a warning when the current of load over the preset threshold...

Page 6: ...On Off button should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update o...

Page 7: ...sight Operating Temperature 0 C 40 C Frequency Range 868 40MHz 869 85MHz EU CN PAN11 1B 2B 3B 8B 908 40MHz 916 00MHz UL 922 927MHz TW JP PAN11 5B Specifications are subject to change and improvement w...