background image

English

Operating instructions

17

Models WITHOUT extraction door:

-

put drain plug [4] in. The slot [37] has to be facing downwards, otherwise the plug
will not go in. Should it prove hard to insert, lubricate gasket [38] with food compat-
ible lubricant;

Models WITH extraction door:

-

fix chute [9] under the door [14] hooking it on hinges [26];

-

fix basin support [10] on the front panel with knobs [16].

7.5

Adjusting blades

T

HESE

 

OPERATIONS

 

MUST

 

BE

 

CARRIED

 

OUT

 

ONLY

 

AFTER

 

DISCONNECTING

 

MACHINE

 

FROM

MAIN

 

POWER

!

Blades must be adjusted whenever they are replaced on the beater.

An incorrect or lack of adjustment of the blades could cause
the formation of ice on the cylinder inner walls, or excessive
wearing of the blades and mechanical stress of the beater.

-

Once the beater is in place, push blade [31] outwards by hand so that scraping
edge is perfectly in line with and matches the cylinder inner surface. At the same
time, tighten fixing screws [36];

-

in case of models supplied with more than one scraping blade, repeat operations
for all blades, placing them evenly.

7.6

Sanitization

Sanitization is an operation similar to rinsing (ref. Par. 7.1). However, this must to be carried out with a solution of warm
water and food compatible disinfectant.

To correctly dose, follow disinfectant's instruction for use. If required, in the final stage of sanitizing, rinse with water only.

On completion of sanitization, close lid and neither touch with your hands, nor wipe with cloths
or paper towels any part of the machine which will come into contact with food.

Check that there is no more water inside the cylinder. If needed, briefly spin the beater to drain any remaining water.

8

M

AINTENANCE

The machine requires a very limited maintenance. Periodically, we suggest to:

-

check the good conditions of the machine's parts;

-

check that electric power cable is not damaged;

-

Try the efficiency of the safety devices (ref. Par. 8.2).

It is then useful to maintain the external panels clean and the surrounding area. Dust, paper fragments or other small objects
may penetrate in the machine through the ventilation loopholes (in particular if equipped with air condensation and rapidly
compromise its correct functioning.

The inside parts, to which the user MUST NOT accede, must be checked by the Assistance Service (ref. Par. 8.3)

Summary of Contents for GEL 20

Page 1: ...Z15 013 0198 V02 ING GEL OPERATING INSTRUCTIONS GEL 20 Ice cream freezer...

Page 2: ...English Ice cream freezer 2...

Page 3: ...AUTIONS 4 2 SAFETY DEVICES 5 2 1 Lid s magnetic sensor 5 2 2 Extraction door s grill 5 3 TECHNICAL DATA 6 3 1 Technical data plate and EC marking 6 3 2 Acoustic pressure level 6 4 CARRYING AND UNPACKI...

Page 4: ...OLES OR DRAIN HOLES DO NOT REMOVE OR HIDE FOR ANY REASON ANY LABEL APPLIED ON THE MACHINE NEVER OPEN THE PROTECTING PANELS THE MACHINE DOES NOT CONTAIN IN ITS INSIDE PARTS WHICH CAN BE OPERATED BY THE...

Page 5: ...en the lid is open In consequence the device can t operate when the lid is open and if it is opened during its functioning the beater immediately stops In any case the lid s magnetic sensor MUST NOT b...

Page 6: ...Technical Data section This data has been measured at 1 meter from the surface of the machine and at 1 60 meters from ground level during the machine s functioning 4 CARRYING AND UNPACKING Note We su...

Page 7: ...op THE OPENING OF THE LATERAL PANEL IS ONLY ALLOWED TO THE ASSISTANCE SERVICE OR TO QUALIFIED TECHNICIANS AND MUST BE MADE BEFORE CONNECTING IT MAKE SURE NOT TO DAMAGE THE INTERNAL PARTS OF THE MACHIN...

Page 8: ...g items are all included in the package lid 5 beater 6 correctly fixed inside the cylinder with its knob 7 and supplied with adjustable blades 31 1 3 according to the model drain plug 4 not in large s...

Page 9: ...rked with appropriate letters phase R or phases R S T neutral N earth the earth pole must be properly recognizable the electrical socket must prevent through appropriate mechanical measures the plug s...

Page 10: ...E BY TURNING THE BEATER S SWITCH 24 BEFORE INTRODUCING YOUR HANDS OR ANY OBJECT INSIDE THE REFRIGERATING CYLINDER Open the lid unscrew the fixing knob 7 pull out the beater 6 from the cylinder then cl...

Page 11: ...ded NOT RESPECTING THESE RULES IN ADDITION TO VOIDING ANY FORM OF WARRANTY CAN SERIOUSLY COMPROMISE THE SAFETY PERFORMANCES AND FUNCTIONING OF THE SAME MACHINE 6 2 Controls and indicators Note Those c...

Page 12: ...oroughly cleaned and sanitized see Section 7 Note if more than one consecutive production cycle is required a rinse between cycles is sufficient ref Par 7 1 alternatively start with light coloured mix...

Page 13: ...eater s Switch 24 to BEATING right wait for completion of cycle which is when Timer knob 32 is again on starting position and the alarm rings when available turn Beater s Switch 24 to STOP centre At t...

Page 14: ...ON OF THE PRODUCTION CYCLE S TO THOROUGHLY DISASSEMBLE WASH AND SANITIZE ANY PARTS OF THE MACHINE WHICH COME INTO CONTACT WITH THE PRODUCT 7 WASHING AND SANITIZING 7 1 Rinse only To remove ice cream r...

Page 15: ...emove lid 5 if necessary remove hinge pin 25 remove drain plug 4 unscrew counterclockwise fixing knob 7 and remove beater 6 RESIDUAL HAZARD BEATER S BLADE ARE SHARP ALONG BOTTOM AND EXTERNAL SIDE EDGE...

Page 16: ...c controls 7 4 Reassembly THESE OPERATIONS MUST BE CARRIED OUT ONLY AFTER DISCONNECTING MACHINE FROM MAIN POWER Assemble blades 31 on beater s supports 6 partially screwing screws 36 Blades will be su...

Page 17: ...venly 7 6 Sanitization Sanitization is an operation similar to rinsing ref Par 7 1 However this must to be carried out with a solution of warm water and food compatible disinfectant To correctly dose...

Page 18: ...res Section contained in the Technical Handbook 8 2 Check of safety devices Every three months check that all safety devices on your machine are in perfect working order open the lid and remove the be...

Page 19: ...ifesavers on the electric plant are closed If they aren t before closing them make sure that no one is making electrical maintenance Cause A protective fuse of the electric plant is cut down Find and...

Page 20: ...eat or frequently repeat call the assistance service Refrigerating system or control circuit are faulty Call Assistance Service Cause Obstacles are placed at the air conditioning s opening at a distan...

Page 21: ...English Operating instructions 21...

Page 22: ...d eventual travelling expenses will be at purchasers charge Freon gas filling is excluded from the warranty The warranty declines if the machine is used not in conformity with the sales instructions i...

Page 23: ...English Operating instructions 23...

Page 24: ...Servizio Assistenza Technical Service Service d Assistance Kundendienst Servicio Asistencia Servicedienst COSTRUTTORE MANUFACTURER CONSTRUCTEUR HERSTELLER CONSTRUCTOR FABRIKANT...

Reviews: