English
Operating instructions
17
Models WITHOUT extraction door:
-
put drain plug [4] in. The slot [37] has to be facing downwards, otherwise the plug
will not go in. Should it prove hard to insert, lubricate gasket [38] with food compat-
ible lubricant;
Models WITH extraction door:
-
fix chute [9] under the door [14] hooking it on hinges [26];
-
fix basin support [10] on the front panel with knobs [16].
7.5
Adjusting blades
T
HESE
OPERATIONS
MUST
BE
CARRIED
OUT
ONLY
AFTER
DISCONNECTING
MACHINE
FROM
MAIN
POWER
!
Blades must be adjusted whenever they are replaced on the beater.
An incorrect or lack of adjustment of the blades could cause
the formation of ice on the cylinder inner walls, or excessive
wearing of the blades and mechanical stress of the beater.
-
Once the beater is in place, push blade [31] outwards by hand so that scraping
edge is perfectly in line with and matches the cylinder inner surface. At the same
time, tighten fixing screws [36];
-
in case of models supplied with more than one scraping blade, repeat operations
for all blades, placing them evenly.
7.6
Sanitization
Sanitization is an operation similar to rinsing (ref. Par. 7.1). However, this must to be carried out with a solution of warm
water and food compatible disinfectant.
To correctly dose, follow disinfectant's instruction for use. If required, in the final stage of sanitizing, rinse with water only.
On completion of sanitization, close lid and neither touch with your hands, nor wipe with cloths
or paper towels any part of the machine which will come into contact with food.
Check that there is no more water inside the cylinder. If needed, briefly spin the beater to drain any remaining water.
8
M
AINTENANCE
The machine requires a very limited maintenance. Periodically, we suggest to:
-
check the good conditions of the machine's parts;
-
check that electric power cable is not damaged;
-
Try the efficiency of the safety devices (ref. Par. 8.2).
It is then useful to maintain the external panels clean and the surrounding area. Dust, paper fragments or other small objects
may penetrate in the machine through the ventilation loopholes (in particular if equipped with air condensation and rapidly
compromise its correct functioning.
The inside parts, to which the user MUST NOT accede, must be checked by the Assistance Service (ref. Par. 8.3)