15
Parameter Value
Description
Default
Exam.1 Exam.2
32
hhhhhh
External access code in
DAY + NIGHT
mode
-
1212
1324
33
hhhhhh
External access code in
DAY
mode
-
2211
2211
34
hhhhhh
External access code in
NIGHT
mode
-
1122
1122
hhhhhh
– password for relay closing from buttons [2 to 6 digits]
The 3 passwords are controlled by Day/Night; the combination is entered using
the unit buttons. It is influenced by the setting of
Relay
mode
and
Day/Night
switchover. When set to
2-group mode
the unit is permanently in
DAY
mode
.
Follow these rules when choosing password combination:
Select passwords carefully, to prevent their discovery from wear on
buttons caused by frequent use.
Select the first password button from infrequently-used buttons for
direct dialling (-extends choice time)(-not valid for keyboard).
Note:
The switchover to
Day/Night mode
remains set in unit even after line
disconnection.
Parameter Value Description
Default
Exam.1 Exam.2
35
aa
Internal access code
55
55
55
aa
– command from phone to relay closing [2 digits]
It is recommended to set the same command for Internal Access Code and
End Call (
parameter 43
)
aa=bb
.
Parametr Value
Description
Default
Exam.1 Exam.2
36
ss
Relay closing time
05
02
05
ss
– duration of relay closing [2 digits 01-99]
Parametr Value
Description
Default
Exam.1 Exam.2
37
pp
Time between 2 impulses
[sec]
05
05
05
pp
– duration of delay between 2 impulses of relay [2 digits 01-99]