19
Parameter Value
Description
Default
Exam.1 Exam.2
57
t
DTMF tone duration (ms)
5
(100ms)
5
(100ms)
5
(100ms)
58
m
Space duration between
DTMF tones (ms)
5
(100ms)
5
(100ms)
5
(100ms)
59
f
Recall duration (ms)
1
(100ms)
1
(100ms)
1
(100ms)
50
p
Pause duration (ms)
8
(800ms)
8
(800ms)
8
(800ms)
t
– DTMF tone duration is determined by the formula:
(entered 5) x 10 = tone duration
[ms]
[range 1-0 i.e. 60-150ms]
m
–
Space duration between DTMF tones
is determined by the formula:
(entered 5) x 10 = gap duration
[ms]
[range 1-0 i.e. 60-150ms]
f
– Recall duration is determined by the formula:
entered number x 100 = Recall duration
[ms]
[range 1-6 i.e. 100-600ms]
p
– Pause duration is determined by the formula:
entered number x 100 = pause duration
[ms]
[range 5-0 i.e. 500-1000ms]
–
p
time is simultaneously the duration of interdigit gap at pulse dialling.
Parameter Value
Description
Default
Exam.1 Exam.2
5*1
x
Number of busy tones
before hahg up
6
6
6
x
– is number of busy tones before hahg up by next table:
x
number of busy tones
x
number of busy tones
1
4
5
8
2
4
6
8
3
6
7
10
4
6
8
10