11
3.4.4 FMB1YX IO Elements
3.4.4.1 CAN Adapter Mode
Sets LVCAN mode:
0 – Auto Detect
,
1 – LV-CAN200
,
2 – ALL-CAN300
,
3 - CAN-CONTROL
.
3.4.4.2 Send data with 0, if ignition is off (ID = 45001)
This parameter enables/disables data sending with 0 value, if ignition is off.
0 – Disable
,
1 –
Enable
.
3.4.4.3 Program Number (ID = 45002)
Sets LVCAN Program number.
3.4.4.4 1
st
LVCAN property parameter priority (ID=45100)
Parameter defines LVCAN property type of priority:
0 is disabled
,
1 – low
,
2 – high
,
3 - panic
.
3.4.4.5 1
st
LVCAN property parameter operand (ID=45101)
Minimum
Value
Maximum
Value
Default
Value
Goes with (depends on
parameters)
Value
Type
0
2
0
Send data with 0, if ignition is off
(ID = 45001)
Program Number (ID = 45002)
Uint8
Minimum
Value
Maximum
Value
Default
Value
Goes with (depends on
parameters)
Value
Type
0
1
0
LVCAN Mode (ID = 45000)
Program Number (ID = 45002)
Uint8
Minimum
Value
Maximum
Value
Default
Value
Goes with (depends on
parameters)
Value
Type
0
999
0
LVCAN Mode (ID = 45000)
Send data with 0, if ignition is off
(ID = 45001)
Uint16
Minimum
Value
Maximum
Value
Default
Value
Goes with (depends on
parameters)
Value
Type
0
1
0
LVCAN Mode (ID = 45000)
Program Number (ID = 45002)
Uint8