16
4. AVL Parameters ID
When no I/O element is enabled, AVL packet comes with GNSS information only. After enabling
I/O element(s) AVL packet along with GPS information contains current value(s) of enabled I/O
element. List of available CAN data, parameter size, ID and value range you can find in
Table 5 ACQUIRED PARAMETRS IO Ids
Property Input
Param
index
Size
(Bytes)
Param
IO ID
Measurement
units
a1
Remarks
CAN-CONTROL
Program number
29
4
100
-
-
Module ID
30
8
101
-
-
Total Mileage
33
4
87
meters
1
Total Mileage (counted) *
34
4
105
meters
1
Fuel Consumed
35
4
83
Ltr * 10
0.1
Fuel Consumed (counted) *
36
4
107
Ltr * 10
0.1
Fuel Level [%]
37
1
89
%
1
Fuel Level [liters]
38
2
84
Ltrs * 10
0.1
Engine RPM
42
2
85
-
1
Engine Temperature
44
1
115
°C x 10
0.1
signed
Accelerator Pedal Position
45
1
82
%
1
Vehicle Speed
46
1
81
km/h
1
Control State Flags
52
4
123
-
-
Security State Flags
61
8
132
-
Battery Level (percent)
81
1
152
%
1
NOTE:
„
Total Fuel Used
“ is sent to server
multiplied by 10
.
Example
: if value was
150.5
liters, „
1505
“ will be sent to server.
*
- Fuel consumed (counted), Total mileage (counted), Engine Work Time (counted) are
parameters, which are counted after CAN-CONTROL is connected to CAN bus.