71
Threshold (ID=1614)
9.6.13
Crash Detection Duration (ID=1613)
Minimum
value
Maximum
value
Recommende
d value
Goes with (depends on)
parameters
Value
type
0
600
-
Crash Detection Enabled/disabled
(ID=1612)
Threshold (ID=1614)
U8
9.6.14
Crash Detection Threshold (ID=1614)
Minimum
value
Maximum
value
Recommende
d value
Goes with (depends on)
parameters
Value
type
16
1600
-
Crash Detection Enabled/disabled
(ID=1612)
Duration (ID=1613)
U8
9.6.15
Towing Detection (ID=1291)
Towing detection can be set to: 0
–
disabled (default), 1
–
low priority event, 2
–
high
priority event.
Minimum
value
Maximum
value
Recommende
d value
Goes with (depends on)
parameters
Value
type
0
2
-
Activation Timeout (ID=1292)
Ignition check after event (ID=1295)
Duration(ID1296)
Acceleration (ID=1297)
Angle(ID=1298)
U8
9.6.16
Towing Detection Activation Timeout (ID=1292)
Activation timeout is time after which FM turns ON Towing detection function if other
requirement is met (Ignition OFF state detected). It is measured in minutes.
Minimum
value
Maximum
value
Recommende
d value
Goes with (depends on)
parameters
Value
type
0
2
-
Towig detection enable/disable
(ID=1291)
Ignition check after event (ID=1295)
Duration(ID1296)
Acceleration (ID=1297)
Angle(ID=1298)
U8
9.6.17
Towing Detection Ignition check after event (ID=1295)
If ignition is OFF, event will be generated when TMO reached.
Minimum
value
Maximum
value
Recommende
d value
Goes with (depends on)
parameters
Value
type
0
2
-
Towig detection enable/disable
U8