Minimum 

value 

Maximum 

value 

Recommended 

value 

Goes with (depends on) 

parameters 

Value 

type 

65535 

60 

Enable/Disable (ID=1101) 

U16 

9.6.37

 

AutoGeofence event Priority (ID=1103) 

 
Parameter defines AutoGeofence event priority: 0 is low, 1 

 high. 

Minimum 

value 

Maximum 

value 

Recommended 

value 

Goes with (depends on) 

parameters 

Value 

type 

Enable/Disable (ID=1101) 

AutoGeofence event generating 

(ID=1104) 

U8 

9.6.38

 

AutoGeofence event generating (ID=1104) 

 
Generate event: 0 

 no event; 1 

 on entering zone; 2 

 on exiting zone; 3 

 on both. 

Minimum 

value 

Maximum 

value 

Recommended 

value 

Goes with (depends on) 

parameters 

Value 

type 

Enable/Disable (ID=1101) 

AutoGeofence event Priority 

(ID=1103)  

U8 

9.6.39

 

Radius (ID=1105) 

Parameter  represents  radius  of  circle  with  center  device  coordinates  after  activating 

AutoGeofence feature. 

Minimum 

value 

Maximum 

value 

Recommended 

value 

Goes with (depends on) 

parameters 

Value 

type 

1000000 

100 

Enable/Disable (ID=1101) 

U32 

9.7

 

Accelerometer parameters 

9.7.1

 

Acceleration range configuration (ID=1290) 

Parameter represents range of movement detection in G force. 

Minimum 

value 

Maximum 

value 

Recommended 

value 

Goes with (depends on) 

parameters 

Value 

type 

16 

Ignition Source (ID=1003) 

U32 

9.7.2

 

Movement filter start (ID=1293) 

Parameter represents how long it takes to generate movement event in seconds. 

Minimum 

value 

Maximum 

value 

Recommended 

value 

Goes with (depends on) 

parameters 

Value 

type 

60 

Ignition Source (ID=1003) 

U32 

9.7.3

 

Movement filer stop (ID=1294) 

Parameter represents how long it takes to change movement I/O element state from 1 to 0 

in seconds. 

Summary of Contents for FM1000 ST

Page 1: ...FM1000 ST User Manual V2 9 This version is suitable for device with universal FM1000 firmware v 00 10 XX Rev 0 and later versions ...

Page 2: ...TING FIRMWARE USING USB CABLE 17 5 OPERATIONAL BASICS 19 5 1 OPERATIONAL PRINCIPALS 19 5 2 SLEEP MODES 19 5 2 1 Sleep mode 19 5 2 2 Deep Sleep mode 20 5 3 VIRTUAL ODOMETER 21 5 4 FEATURES 21 5 4 1 Scenarios 21 5 4 2 Trip 22 5 4 3 Geofencing 22 5 4 4 Towing Detection 22 5 5 CONFIGURATION 23 5 6 CONFIGURATOR 23 5 7 RECORD STORAGE 26 5 8 SYSTEM SETTINGS 26 5 9 RECORD SETTINGS 27 5 10 GSM SETTINGS 28 ...

Page 3: ...COMMANDS 53 8 DEBUG MODE 55 9 PARAMETER LIST 56 9 1 PARAMETERS VALUE TYPES 56 9 2 SYSTEM PARAMETERS 56 9 2 1 Sleep Mode ID 1000 56 9 2 2 Sleep timeout ID 1001 56 9 2 3 Mode Switch Source ID 1002 57 9 2 4 Ignition Source ID 1003 57 9 2 5 Static navigation settings ID 1004 57 9 2 6 Saving Sending without time synchronization ID 1005 57 9 2 7 Power Voltage Low Level ID 1006 57 9 2 8 Power Voltage Hig...

Page 4: ...1560 65 9 5 3 2 Min Saved Records ID 1563 65 9 5 3 3 Send Period ID 1564 65 9 5 3 4 GPRS Week Time ID 1565 65 9 5 4 Roaming Network GSM operator code Vehicle MOVING parameters 65 9 5 4 1 Min Period ID 1570 65 9 5 4 2 Min Distance ID 1571 66 9 5 4 3 Min Angle ID 1572 66 9 5 4 4 Min Saved Records ID 1573 66 9 5 4 5 Send Period ID 1574 66 9 5 4 6 GPRS Week Time ID 1575 66 9 5 5 Unknown Network GSM op...

Page 5: ... ID 1033 74 9 6 32 Geofence Zone 1 Latitude Y1 ID 1034 74 9 6 33 Geofence Zone 1 Longitude X2 ID 1035 75 9 6 34 Geofence Zone 1 Latitude Y2 ID 1036 75 AutoGeofencing 75 9 6 35 Enable Disable ID 1101 75 9 6 36 Activation Timeout ID 1102 75 9 6 37 AutoGeofence event Priority ID 1103 76 9 6 38 AutoGeofence event generating ID 1104 76 9 6 39 Radius ID 1105 76 9 7 ACCELEROMETER PARAMETERS 76 9 7 1 Acce...

Page 6: ... interface Please use cables provided with FM1000 device Teltonika is not responsible for any harm caused by using wrong cables for PC FM1000 connection Warning Do not use FM1000 device if it distracts driver or causes inconvenience due to OBD II placement Device must not interfere with driver 1 2 Instructions of safety This chapter contains information on how to operate FM1000 safely By following...

Page 7: ...t Direct Current I O Input Output Record AVL data stored in FM1000 memory AVL data contains GNSS and I O information AVL packet data packet that is being sent to server during data transmission AVL packet contains from 1 to 50 records 2 BASIC DESCRIPTION FM1000 is a terminal with GNSS and GSM connectivity which is able to determine the object s coordinates and transfer them via the GSM network Thi...

Page 8: ...y 10 16V USB port CAN K Line Ignition input LEDs indicating device status Note Ignition input parameter depends on vehicle mark and model Special features Any element event triggers speed external voltage etc Highly configurable data acquisition and sending Multiple Geo fence areas Sleep mode Deep sleep mode Configurable scenarios available Real time process monitoring Authorized number list for r...

Page 9: ...urrent average 121 mA Deep Sleep average less than 4 mA2 Operation temperature 25 C 55 C Storage temperature 40 C 70 C Storage relative humidity 5 95 no condensation Modem LED LED GNSS Internal GNSS antenna GSM Internal GSM antenna OBD II connector Standard OBD II connector USB Mini USB socket Table 1 FM1000 specifications 1 Energy consumption has been tested at 12V voltage 2 When in Deep Sleep mo...

Page 10: ...10 Figure 1 FM1000 view dimensions tolerance 1 mm ...

Page 11: ... 10 16 V Digital Input Input resistance Ignition 15 kΩ Input Voltage Recommended Operating Conditions 0 Supply voltage V Input Voltage threshold Ignition 5 V 2 5 Absolute Maximum Ratings VALUE CHARACTERISTIC DESCRIPTION Min Typ Max Unit Supply Voltage Absolute Maximum Ratings 16 16 V Digital Input Ignition Voltage Absolute Maximum Ratings 32 32 V ...

Page 12: ...12 3 CONNECTION PINOUT 3 1 How to insert SIM card into FM1000 device Gently open FM1000 case using screwdrivers Remove FM1000 case Insert SIM card as shown ...

Page 13: ...ng system 32 bit and 64 bit Windows XP with SP3 or later Windows Vista Windows 7 Windows 8 MS NET Framework V3 5 or later http www microsoft com or http avl1 teltonika lt downloads tavl Framework dotnetfx35setupSP1 zip Drivers Please download Virtual COM Port drivers from Teltonika website http avl1 teltonika lt downloads FM1000 vcpdriver_v1 3 1_setup zip ...

Page 14: ... used to detect FM1000 device connected to the computer Click Next in driver installation window figures below Figure 2 Driver installation window This will launch device driver installation wizard In the following window click Next button again Figure 3 Driver installation window ...

Page 15: ...GNSS signal is not received Blinking every second Normal mode GNSS is working Off GNSS is turned off because Deep sleep mode Or GNSS antenna short circuited 3 4 Status LED Behavior Meaning Blinking every second Normal mode Blinking every 2 seconds Deep sleep mode Blinking fast for a short time Modem activity Blinking fast constantly Boot mode Off Device is not working Or Device firmware being flas...

Page 16: ... 16 V DC Power range 10 16 V DC to ground 3 6 USB Mini USB connector Figure 6 Mini USB type B connector FM1000 connected to PC creates an STM Virtual COM Port which can be used as a system port to flash firmware and configure the device Table 2 OBD II pinout description Figure 5 OBD II pinout ...

Page 17: ...h device is connected click connect and when IMEI and Firmware version fields are filled start the update Device needs some time to send IMEI and Firmware version so do not be afraid if IMEI will not show up immediately disconnect and after 1 2 minutes try to connect again When starting update device will open link with updater With link open device downloads firmware and starts installing Wait th...

Page 18: ...18 Figure 8 FM1000 firmware updater screen Figure 9 Firmware updating processes ...

Page 19: ...OMMAND LIST section Module configuration can be performed over TCP or via SMS Configuration parameters and modes are described in FMXXXX Protocols document 5 2 Sleep modes 5 2 1 Sleep mode FM1000 is able to go to Sleep mode after configurable Sleep timeout This timeout defined period starts counting when device is in STOP mode After timeout is reached and all conditions for sleep mode are met devi...

Page 20: ...r deep sleep mode if ALL of these conditions are met FM1000 has to be configured to work in Deep Sleep mode Device must be synchronized time with GNSS satellites FM1000 has to be in X on Stop Mode Configured by Mode switch parameter Movement by accelerometer is not detected Ignition Configured to be detected by Power Voltage Ignition or Accelerometer is off Min Record Saving Period Data Acquisitio...

Page 21: ...tection Alarm Crash detection Unplug detection Green Driving Scenario Helps to prevent and inspect driver about harsh driving Scenario continuously monitors accelerating force braking force and cornering angles To save GPRS traffic Green Driving event will be generated included into records only when FM1000 measured values are higher than those set in configuration without additional I O settings ...

Page 22: ...e value of trip start will be 2 or 3 2 being private trip and 3 business Note Scenarios and Trip features are activated only if Ignition Configured to be detected by Power Voltage Ignition or Accelerometer is turned on 5 4 3 Geofencing Geofencing is another feature which is highly customizable and can detect wherever car enters or leaves customized areas More about Geofencing can be read in 5 11 3...

Page 23: ... that MS Net Framework 3 5 or later is installed on your PC before starting configurator Latest MS Net Framework version can be downloaded from official Microsoft web page Module configuration is performed over USB cable Configuration process starts from starting FM1000 Configurator program and then connecting to FM1000 device via Connect button located on the top left corner of configurator If co...

Page 24: ...ce configuration Just click Advanced Configuration button on lower right corner in configurator and new menu options appears figure 12 You can always go back to recommended configuration menu only by clicking Recommended Configuration button in main button area area 1 For further device configuration in Advanced mode read description below Connect device to configurator Save configuration and disc...

Page 25: ...saves configuration parameters to FM1000 Flash memory Load Defaults loads default FM1000 settings that later can be modified This procedure must be performed before entering new parameters Save to File allows user to save currently entered settings to XML file for later usage Load from File allows user to load configuration saved in XML extension file Reset device reboots FM1000 and displays proce...

Page 26: ...ers Sleep settings where user can turn sleep deep sleep on or off Mode Switch Settings where user can configure 3 ways how FM1000 will change its working mode Ignition Settings where user can configure ignition detection source for ignition source Ignition Source can be selected as Power Voltage Digital Input 1 Movement or OBD This parameter has influence on all FM1000 application If ignition sour...

Page 27: ...ter Internal accelerometer does not detect movement Internal accelerometer detects movement GNSS GNSS fix is available and vehicle speed is lower than 5 km h GNSS fix is available and vehicle speed is higher than 5 km h While GNSS fix is unavailable Object Motion Detection Settings are working like in Movement mode Figure 13 System settings configuration 5 9 Record settings Here user can modify if...

Page 28: ...supports backup server If main server is not responding FM1000 connects to backup server and still sends records for 5 min MAX or until link is not closed can be closed by configurable Active link TMO parameter Both servers have the same configurable parameters Some operators use specific authentication for GPRS session CHAP or PAP If any of these is used APN should be entered as chap APN or pap A...

Page 29: ...MS would not be sent Figure 16 SMS configuration Note A mobile phone will not understand SMS with binary code so sending it to a mobile phone is useless When sending a binary SMS to a phone number which is a server phone number the server can interpret and understand binary code so the data can be read and you can view it on the server SMS login and password and authorized number list are used to ...

Page 30: ...ured SMS message to a defined phone number If SMS events is activated but there are no numbers defined in SMS events PreDefined Numbers list figure 18 then the device will not send any messages Figure 18 SMS Events PreDefined Numbers list The sent SMS messages format is according to Date Time EventText ...

Page 31: ...n be saved in memory all other messages will not be saved until there is room in device memory FM1000 sends SMS event message when a configured property enters and or exits its configured High Low boundaries or Hysteresis event generation is chosen Monitoring does not generate event so SMS event could not be configured Every element of SMS event can be configured to send individual message to diff...

Page 32: ...roaming or vice versa e g vehicle passes through country boarder Unknown profile switches on when device can t find home operator or no operator reachable from roaming list If current GSM operator is defined as Home Operator device will work in Home5 Data Acquisition mode if current operator is defined as Roaming Operator device will work in Roaming Data Acquisition mode and if device can t find h...

Page 33: ...Mode configuration Min Saved Records defines minimum number of coordinates and I O data that should be transferred with one connection to server If FM1000 does not have enough records to send to server it will check again after time interval defined in Sending Period Send period GPRS data sending to server period Module makes attempts to send collected data to server every defined period If it doe...

Page 34: ...sion is alive FM1000 sends data to server according to Send period parameter If it is not FM1000 checks if it is able to re establish the session Figure 21 GPRS Week Time configuration Device checks if the time between last saved record and current time is equal or higher than Time based acquire interval If so FM1000 saves record to memory If not FM1000 checks if the distance from last record to c...

Page 35: ...ameter value Entering zero disables data acquisition depending on distance Min distance Angle based data acquiring Min angle records are being acquired when angle difference between last recorded coordinate and current position is greater than defined value Entering zero disables data acquisition depending on angle Min angle Features settings 5 11 1 Scenarios settings In Scenarios window seven dif...

Page 36: ...ord canceled Unplug Detection Eventual event will be generated when FM1000 is unplugged from OBD socket User can select detection type simple used in cars where power voltage is not dependant on ignition recommended advanced used in cars where power voltage is disconnected when ignition is switched off Crash detection Eventual Record is generated when device detects car accident using the internal...

Page 37: ...rds from GPS Continuous from GPS or Continuous from OBD Continuous distance counting Trip distance is going to be counted continuously from Trip start to Trip stop This value is written to I O Odometer value field When Trip is over and next Trip begins Odometer value is reset to zero When the next trip starts device starts to count distance continuously from zero Figure 23 Trip configuration Figur...

Page 38: ...NSS errors some records are made inside area and some outside Event is generated only when both borders are crossed See figure 26 for details blue track is considered to have entered the area while red track is not Figure 26 Geofence border Shape can be rectangle or circle Priority priority of Geofence event low high or panic These levels define priority of event information sending to server See ...

Page 39: ...an be configured by following parameters visible in figure 28 below Activate Enable or Disable AutoGeofence functionality Activation TMO Time period before Geofence is activated after vehicle stops Priority Priority of generated event which will be applied to saved record Enter Event Event generation on Geofence entrance Exit Event Event generation on Geofence exit On Both Event generation on Geof...

Page 40: ...eatures is reached When Activation Timeout is reached and Ignition is still in OFF state FM monitors accelerometer data If Acceleration or Angle value reaches configured threshold for configured Duration in ms check Ignition state If Ignition is still OFF during configured Ignition check after Event Timeout time then event is generated If configured sends sms event or makes a call Function will be...

Page 41: ...nal Voltage Voltage mV 0 30 V 3 GPS Speed GPS speed km h 4 Trip Distance Distance between trip start and trip stop m 5 Total Distance Total driven distance km 6 GSM Signal GSM signal level value in scale 1 5 7 Movement 0 not moving 1 moving 8 Battery Voltage Battery voltage mV 9 Deep sleep 0 not deep sleep mode 1 GPS sleep mode 2 Deep sleep mode 3 Online deep sleep mode 10 Battery Current Battery ...

Page 42: ...rmanent I O elements simple monitoring and event generating Monitoring method is used when current I O information needed with regular GNSS coordinates Event generating method is used when additional AVL packet is needed when current value of I O exceeds predefined High and Low levels I O settings allow defining I O event criteria Figure 30 I O settings Enabled or disabled field allows enabling I ...

Page 43: ...leaving predefined range it must have same value for Averaging constant time 1 Averaging constant value equals about 100 milliseconds Param AvgConst sek 10 For example Value 3 300ms In Deep Sleep mode there is no Averaging Note I O element s Movement Averaging constant is interpreted as Start Move Timeout in seconds from 1 to 59 Start Move Timeout is a time interval required for accelerometer to b...

Page 44: ...aud 4 ISO 14230 4 KWP 5 baud init 10 4 kbaud 5 ISO 14230 4 KWP fast init 10 4 kbaud 6 15765 4 CAN 11 bit ID 500 kbaud 7 ISO 15765 4 CAN 29 bit ID 500 kbaud 8 ISO 15765 4 CAN 11 bit ID 250 kbaud 9 ISO 15765 4 CAN 29 bit ID 250 kbaud 10 SAE J1939 CAN 29 bit ID 250 kbaud 5 13 2 Data Data is saved as I O elements OBD I O elements must be enabled using configurator All OBD elements are configured in sa...

Page 45: ... window OBD IO list Name Param PID HEX DEC values Min Max Unit Size Multiplier Number of DTC 01 01 0 255 1B x1 Calculated engine load value 04 04 0 100 1B x1 Engine coolant temperature 05 05 40 215 C 1B x1 Short term fuel trim 1 06 06 100 99 1B X1 Fuel pressure 0A 10 0 765 kPa 2B X1 Intake manifold absolute pressure 0B 11 0 255 kPa 1B X1 Engine RPM 0C 12 0 16383 rpm 2B X1 Vehicle speed 0D 13 0 255...

Page 46: ...essure 33 51 0 255 kPa 1B X1 Control module voltage 42 66 0 65535 mV 2B X1 Absolute load value 43 67 0 25700 2B X1 Ambient air temperature 46 70 40 215 C 1B X1 Time run with MIL on 4D 77 0 65535 min 2B X1 Time since trouble codes cleared 4E 78 0 65535 min 2b X1 Absolute fuel rail pressure 59 89 0 65535 kPa 2B X10 Hybrid battery pack remaining life 5B 91 0 100 1B X1 Engine oil temperature 5C 92 40 ...

Page 47: ...ive the SMS when it wakes up exits deep sleep mode 6 1 SMS command list Command Description Response getstatus Modem Status information Yes getweektime Current device time Day of Week and amount of minutes passed since start of week Yes getops List of currently available GSM operator Yes getcfgtime Date and Time of last successful configuration Yes ggps Google Map Link information Yes getgps Curre...

Page 48: ...owing Detection Yes 6 1 1 getstatus Response details Description Data Link Indicate module connection to server at the moment 0 Not connected 1 connected GPRS Indicate if GPRS is available at the moment Phone Voice Call status 0 ready 1 unavailable 2 unknown 3 ringing 4 call in progress 5 asleep SIM SIM Status 0 ready 1 pin 2 puk 3 pin2 4 puk2 OP Connected to GSM Operator numerical id of operator ...

Page 49: ... Configuration was performed on 2010 4 15 5 45 19 6 1 5 ggps Response details Description D Date T Time S Actual Speed C Latitude Last good Latitude Longitude Last good Longitude Url Google Maps Link Example D 2013 7 4 T 0 0 0 S 0 C 0 0 Url http maps google com q 0 0 om 1speed 0 6 1 6 getgps Response details Description GNSS Indicates valid 1 or invalid 0 GNSS data Sat Count of currently available...

Page 50: ...ata Mode state 0 Home and Stop 1 Home and Moving 2 Roaming and Stop 3 Roaming and Moving 4 Unknown and Stop 5 Unknown and Moving Example INI 2007 8 24 10 15 RTC 2007 8 24 12 43 RST 2 ERR 11 SR 182 BR 0 CF 0 FG 0 FL 0 UT 0 SMS 2 NOGNSS 0 0 GNSS 3 SAT 7 RS 5 MD 0 6 1 8 getver Response details Description Code Ver Firmware version Rev Firmware revision Device IMEI IMEI Device ID Device ID is used to ...

Page 51: ...Example I O ID 3 Value 0 6 1 12 getparam Read parameter value ID consists of 3 or 4 digits Detailed list of parameters and IDs can be found in chapter number 8 Parameter List Example getparam 1245 command will request server IP address 6 1 13 setparam Sets new value for parameter ID consists of 3 or 4 digits Detailed list of parameters and IDs can be found in chapter number 8 Parameter List Exampl...

Page 52: ...ed operators Example when no operators are banned 0000 00s 0 000 6 1 16 crashlog Gives the last information before the device has crashed for unexpected reasons It is useful when the device acts unexpectedly or restarts for unexplained reasons Example if no unexpected reset Crash Example if unexpected reset was detected Crash 3051 3052 3053 6 1 17 defevt This SMS command resets SMS Events configur...

Page 53: ...eceive firmware version GET NETWORK Get GSM operator to which device is connected GET IMSI Get IMSI of the device DO REPORT Save a record DO RESET XXX Reset FM5302 or GPS module XXX FM5X or GPS GET ROAMINGX Y Get operator from the list of a certain profile X profile Y operator number in a list SET ROAMINGX Y Z Set operator to the list of a certain profile X profile Y operator number in a list Z op...

Page 54: ...le VIN number GET FAULTCODES Reads fault codes from OBD There is also a possibility to send the same messages as in SMS command list chapter 6 Command Description getstatus Modem Status information getweektime Current device time Day of Week and amount of minutes passed since start of week getops List of currently used and available GSM operators readops Emergency gsm operator readout from active ...

Page 55: ...nd for additional information on how to send GPRS commands please contact to your local sales representative 8 Debug mode FM1000 is able to transmit its current state when connected to PC using USB cable It is used to detect errors and provide information to possible solutions when operating as unexpected Download Terminal from http avl1 teltonika lt Downloads Software Terminal zip After launching...

Page 56: ...le reduces level of power usage by turning GNSS module to sleep in deep sleep mode value 2 module turns GNSS module to sleep and switch GSM module off note that FM1000 do not receive SMS while in deep sleep Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2 U8 9 2 2 Sleep timeout ID 1001 Sleep timeout is time after which FM1000 goes to sleep or deep sleep ...

Page 57: ...tings ID 1004 When static navigation is enabled FM1000 filters out GPS jumps when it is not moving When it is disabled it does not make any changes to collected GPS data 0 disabled default 1 enabled Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 U8 9 2 6 Saving Sending without time synchronization ID 1005 When this feature is enabled value 1 then recor...

Page 58: ...alue Goes with depends on parameters Value type 0 1 U8 9 3 Records parameters 9 3 1 Sorting ID 1010 Record sorting parameter is responsible for record sorting order Value of 0 arranging data starting from the newest while value of 1 arranging data starting from the oldest Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 U8 9 3 2 Active Data Link Timeout ...

Page 59: ...s more frequent then the operator will not disconnect the device form the server 9 4 GSM parameters 9 4 1 GPRS content activation ID 1240 Parameter allows or does not allow GPRS usage If GPRS is not allowed value is 0 if GPRS is allowed value is 1 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 APN Name ID 1242 APN username ID 1243 APN Password ID 1244 ...

Page 60: ...ddress for backup server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 50 char string GPRS content activation ID 1240 Main Server Domain ID 1245 S8 16 9 4 7 Target Main Server Port ID 1246 Parameter defines AVL data destination main server port number Example 12050 Minimum value Maximum value Recommended value Goes with depends on parameters Value type ...

Page 61: ...ent to device Example ba321 Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 5 char SMS Password ID 1253 S8 5 9 4 12 SMS Password ID 1253 User password is used to ensure module security Used in every SMS that is sent to device Example ab123 Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 5 char S8 5 9 4 13...

Page 62: ...ist ID 1271 Parameter defines operator list According to this list module selects operator in home and roaming network GSM operator codes are comma separated example 24601 24602 24705 24503 Minimum value Maximum value Recommended value Goes with depends on parameters Value type Empty 7 digits U32 9 5 Data Acquisition Modes parameters 9 5 1 Home Network GSM operator code Vehicle on STOP parameters ...

Page 63: ...module should connect to GPRS send SMS on Monday second bit on Tuesday and so on up to seventh bit which means Sunday Eighth bit MSB is not used If bits value is 0 then device is not allowed to open GPRS context but if it is already open does not close it If value is 1 it will work as day minutes are defined in rest of the bytes Day s minutes are defined by 18 bytes 144 bits Every nth bit beginnin...

Page 64: ...ees in order to acquire new record If angle difference between last recorded coordinate and current position is greater than defined value new record is stored This parameter is operational when speed is higher than 10km h If value is 0 it means no records by min angle will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 180 Min Period ID 1550 Mi...

Page 65: ... value Recommended value Goes with depends on parameters Value type 1 255 1 GPRS Week Time ID 1565 U8 9 5 3 3 Send Period ID 1564 This parameter indicates frequency time interval in seconds of sending data to server Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Saved Records ID 1563 GPRS Week Time ID 1565 U32 9 5 3 4 GPRS Week Time ID 1565 R...

Page 66: ...m h If value is 0 it means no records by min angle will be saved Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 180 Min Period ID 1570 Min Angle ID 1572 GPRS Week Time ID 1575 U16 9 5 4 4 Min Saved Records ID 1573 This parameter defines minimum number of records in one data packet that can be sent to server It has higher priority than Data Send Period ID...

Page 67: ... Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2592000 Min Saved Records ID 1583 GPRS Week Time ID 1585 U32 9 5 5 4 GPRS Week Time ID 1585 Read GPRS Week Time ID 1545 9 5 6 Unknown Network GSM operator code Vehicle MOVING parameters 9 5 6 1 Min Period ID 1590 This parameter indicates time interval in seconds in order to acquire new record If value is 0 ...

Page 68: ...ime ID 1575 U16 9 5 6 4 Min Saved Records ID 1593 This parameter defines minimum number of records in one data packet that can be sent to server It has higher priority than Data Send Period ID 1594 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 1 255 1 Min Period ID 1590 Min Distance ID 1591 Min Angle ID 1592 GPRS Week Time ID 1595 U8 9 5 6 5 Send Period I...

Page 69: ... braking event Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 25 0 85 0 35 Scenarios Enable ID 1600 Float 9 6 4 Max Angular Velocity ID 1604 It is max allowed cornering angle which can be reached while cornering without triggering harsh cornering event Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 1 0 Scenar...

Page 70: ...y can be set to 0 disabled 1 low sensitivity 2 normal sensitivity default 3 high sensitivity Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 3 U8 9 6 10 Alarm ID 1610 Alarm can be set to generate low or high priority event 0 disabled default 1 low priority event 2 high priority event Minimum value Maximum value Recommended value Goes with depends on param...

Page 71: ...ameters Value type 0 2 Activation Timeout ID 1292 Ignition check after event ID 1295 Duration ID1296 Acceleration ID 1297 Angle ID 1298 U8 9 6 16 Towing Detection Activation Timeout ID 1292 Activation timeout is time after which FM turns ON Towing detection function if other requirement is met Ignition OFF state detected It is measured in minutes Minimum value Maximum value Recommende d value Goes...

Page 72: ...is off Minimum value Maximum value Recommende d value Goes with depends on parameters Value type 0 2 Towig detection enable disable ID 1291 Activation Timeout ID 1292 Ignition check after event ID 1295 Duration ID1296 Angle ID 1298 U8 9 6 20 Towing Detection Angle ID 1298 It is max allowed cornering angle which can be reached while ignition is off Minimum value Maximum value Recommende d value Goe...

Page 73: ... source driven distance is counted Possible values are 0 between records from GPS 1 continuous from GPS default 2 continuous from OBD Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2 U8 9 6 25 Trip Continuous distance counting This parameter removed from FM1000 firmware version 00 06 xx Odometer is always counting distance continuously from Trip start to...

Page 74: ...g zone value 2 d On both value 3 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 3 All Geofencing parameters U8 9 6 31 Geofence Zone 1 Longitude X1 ID 1033 Parameter has two meanings dependent on zone shape If shape is a rectangle then ID 10333 is left down corner X coordinate If shape is a circle then ID 1033 is center of that circle X coordinate Sample ...

Page 75: ...loat 9 6 34 Geofence Zone 1 Latitude Y2 ID 1036 If shape is rectangular then ID 1036 is right upper corner Y coordinate If shape circle ID 1036 is not used Minimum value Maximum value Recommended value Goes with depends on parameters Value type 90 90 All Geofencing parameters Float Other 4 GeoFence zone s parameters have the same logic as shown in GeoFence Zone 1 GeoFence Zone Number Geofence Zone...

Page 76: ...dius ID 1105 Parameter represents radius of circle with center device coordinates after activating AutoGeofence feature Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1000000 100 Enable Disable ID 1101 U32 9 7 Accelerometer parameters 9 7 1 Acceleration range configuration ID 1290 Parameter represents range of movement detection in G force Minimum value ...

Page 77: ...rity 0 is low 1 high 2 panic Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 2 0 I O 1 property parameter ID 1300 I O 1 High level ID 1302 I O 1 Low level ID 1303 I O 1 logic operand ID 1304 I O 1 averaging length ID 1305 S8 9 8 3 I O 1 High level ID 1302 Parameter defines high value of triggered I O property This parameter is used to set thresholds for I...

Page 78: ...nds on parameters Value type 0 4 3 I O 1 property parameter ID 1300 I O 1 priority ID 1301 I O 1 High level ID 1302 I O 1 Low level ID 1303 I O 1 averaging length ID 1305 S8 9 8 6 I O 1 averaging length ID 1305 Parameter defines I O property sample length to average If no averaging needed default value is 1 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 ...

Page 79: ...15 I O 12 GSM Area Code 1420 1425 I O 13 Battery Voltage 1430 1435 I O 14 Battery Current 1440 1445 I O 15 Total distance 1450 1455 9 9 OBD parameters 9 9 1 OBD Interface ID 2100 Enable value 1 disable value 0 Minimum value Maximum value Recommended value Goes with depends on parameters Value type 0 1 U8 9 9 2 OBD I O Configuration OBD I O configuration is the same as general I O See I O parameter...

Page 80: ...ameter defines I O property value Possible values enabled 1 disabled 0 I O 1 priority ID 1301 Parameter defines I O property type of priority 0 is low 1 high 2 panic I O 1 High level ID 1302 Parameter defines high value of triggered I O property This parameter is used to set thresholds for I O properties to generate events I O 1 Low level ID 1303 Parameter defines low value of triggered I O proper...

Page 81: ...ormat setparam X Y W Z X ID Y Enable Disable 0 1 W Telephone number INDEX See 9 4 15 SMS Event Predefined Numbers paragraph ID 150 INDEX 1 ID151 INDEX 2 Z SMS Text Example setparam 100 1 5 Digital Input 1 Event Other I O element SMS events can be configured in same logic All I O element SMS event IDs are listed in the next table OBD Iox x any number between 1 to 20 defines SMS event text for confi...

Page 82: ...0 129 OBD IO11 130 OBD IO12 131 OBD IO13 132 OBD IO14 133 OBD IO15 134 OBD IO16 135 OBD IO17 136 OBD IO18 137 OBD IO19 138 OBD IO20 139 Geo Zone 1 140 Geo Zone 2 141 Geo Zone 3 142 Geo Zone 4 143 Geo Zone 5 144 Auto Geofence 145 Trip 146 OverSpeeding 147 Exc Idling 148 Green Driving 149 Unplug Detection 160 Crash Detection 161 Alarm 162 Towing Detection 163 ...

Page 83: ...rn on device is ready to use Figure 38 OBD II extension cable Installation recommendations 1 SIM card should be inserted in the module while the connector is plugged off while module has no power 2 Please make sure that the module is firmly embedded in the OBD II connector or optional extension cable if there is not enough space for the device near the OBD II connector an extension cable may be ne...

Page 84: ... Start Move Timeout in seconds from 1 to 59 Start Move Timeout is a time interval required for accelerometer to be in the moving state to consider vehicle as moving Warning Do not use FM1000 device if it distracts driver or causes inconvenience due to OBD II placement Device must not interfere with driver ...

Page 85: ...agnostic SMS commands descriptions 9 2015 12 16 1 8 Firmware update using USB description updated and some other minor changes 10 2016 02 01 1 9 Removed Fuel consumption calculation description Corrected Operator list description Corrected Data Acquisition Modes description 11 2016 05 06 2 0 Added SCAN function description Added information about internal battery Watt hour Wh 12 2016 05 20 2 1 Add...

Reviews: