82
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
-2147483647 2147483647
1
I/O#1 Priority (ID=2000)
I/O#1 averaging length (ID=2004)
S32
8.7.3
I/O#1 Low level (ID=2002)
Parameter defines low value of triggered I/O property. This parameter is used to set
thresholds for I/O properties to generate events.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
-2147483647 2147483647
0
I/O#1 Priority (ID=2000)
I/O#1 averaging length (ID=2004)
S32
8.7.4
I/O#1 event generation type (ID=2003)
Parameter defines when event is sent: 0 – on range exit, 1 – on range entrance, 2 – both,
3 – monitoring, 4 – hysteresis, 5 – on changes.
Minimal
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
4
3
I/O#1 Priority (ID=2000)
I/O#1 averaging length (ID=2004)
S8
8.7.5
I/O#1 averaging length (ID=2004)
Parameter defines I/O property sample length to average. If no averaging needed default
value is 1.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
1
I/O#1 Priority (ID=2000)
S32
Other I/O property elements can be configured in same logic. All I/O element parameters
are listed in the next table.