111
to server, if VIN length >9 and <= 16, then two IO ID’s will be sent to server (105,106), and if VIN
length > 16 and <= 24 then three IO ID’s will be sent to server (105,106,107).
FMS-standard SW version supported:
Information that identifies which issue level of the FMS-standard document the software
included in the FMS gateway
supports. Four bytes, representing xx.yy type revision level identification.
Information to be ASCII equivalent of the numeric revision level of the FMS document, 00.01 to
99.99. The first released version will be 01.00.
Note:
Byte 2 and byte 3 represents the SW version supported for trucks. Version number in the format
ab.cd where Byte 2 represents “a” ASCII and Byte 3 represents “b” ASCII.
Byte 4 and byte 5 represents the SW version supported for bus and coaches; version number in
the format ab.cd where
Byte 4 represents “c” ASCII and Byte 5 represents “d” ASCII.
Data Length: 4 bytes
Resolution: ASCII, 0 offset
Data Range: 0 to 255 per byte Operational Range: same as data range
Type: Measured
Supporting information:
PGN 64977
Note: Firmware sends 4 bytes, which should be interpreted as xx.yy.
FMS-standard diagnostics supported:
Status signal which indicates if the FMS Vehicle Interface (FMS Gateway) supports the handling
of diagnostic messages from the vehicle network onto the FMS network.
The FMS gateway does NOT support the re-broadcast of diagnostics messages present on the
vehicle network.
If this ‘FMS-standard Diagnostics Supported’ feature is supported by the FMS Gateway, the FMS
Gateway will support the requests for diagnostics information (from the FMS device) onto the
vehicle network and pass the responses onto the FMS network.
Note: This feature of the FMS Gateway is independent of the ‘FMS-standard Requests
Supported’. The FMS Gateway may support diagnostics without supporting the ‘FMS-standard
Requests Supported’ function, or visa-versa.
00 Diagnostics Is Not Supported
01 Diagnostics Is Supported
10 Reserved
11 Don’t care
Data Length: 2 bits
Resolution: 4 states/2 bit, 0 offset
Data Range: 0 to 3 Operational Range: same as data range
Type: Status
Supporting information:
PGN 64977
Note: Firmware captures all values [0x00-0x03].
Summary of Contents for FM6320
Page 1: ...FM6320 User Manual V1 13...