62
Parameter
ID
Parameter value
Value
type
MIN
MAX
Default
Recommended
AutoGeofencing parameters (chapter 6.3.1.3.4.2)
Autogeofence
x290
Deactivate By
0 (Ignition)
1 (iButton)
0
-
U8
Activation Timeout (in
seconds)
0
65535
60
60
U16
Min Angle (in degrees)
0
180
0
-
U16
Zone #1 priority
0
7
1
1
U8
0
Low
1
High
2
Panic
4
SW21
5
SW22
6
SW23
Zone #1 Generate
Event
0
3
0
2
U8
0
No Event
1
On enter
2
On exit
3
On both
Radius (in meters)
0
9999999
100
100
U32
Configuring format:
<deactivateBy>,<tmo>,<priority>,<eventGenerating>,<radius>
iButton List (chapter 6.3.1.3.5)
Authorized iButtons
500-
999
0
FFFFFFFF
-
U64
FFFFFFFF
Features parameters (chapter 5.6)
Ignition source
x900
0
5
0
-
U8
0
Power
voltage.
1
Din 1
2
Din 2
3
Din 3
4
Din 4
5
Movement
High Level (for
Ignition)
x901
0
30000
0
-
U16
Low Level (for
Ignition)
x902
0
30000
0
-
U16
Summary of Contents for FM6320