background image

 

13 

FMB125 | 

Wiki

 

FEATURES 

Sensors 

Accelerometer 

Scenarios 

Green Driving

Over Speeding detection

Jamming detection

GNSS Fuel Counter

DOUT Control Via Call

Excessive Idling 

detection

Immobilizer

iButton Read 

Notification

Unplug detection

Towing 

detection

Crash detection

Auto Geofence

Manual Geofence

Trip

 

Sleep modes 

GPS Sleep

Online Deep Sleep

Deep Sleep

Ultra Deep Sleep 

 

Configuration and firmware update 

FOTA Web

FOTA

Teltonika Configurator

 

(USB, Bluetooth), 

FMBT mobile application

 

(Configuration)

 

SMS 

Configuration, Events, DOUT control, 
Debug 

GPRS commands 

Configuration, DOUT control, Debug 

Time Synchronization 

GPS, NITZ, NTP 

Fuel monitoring 

LLS (Analog), 

LV-CAN200

ALL-CAN300

OBDII dongle

,  RS232/RS485 fuel sensor, 

CAN-CONTROL

 

Ignition detection 

Digital Input 1, Accelerometer, External 
Power Voltage, Engine RPM (CAN Adapters, 
OBDII dongle) 

RS232

 

Log Mode, NMEA, LLS, LCD, RFIH HID/MF7, 
Garmin FMI, TCP SCII/Binary 

RS485

 

Log Mode, NMEA, LLS, TCP SCII/Binary 

 

 

 

Autogoods “130”

130.com.ua

Summary of Contents for FMU125

Page 1: ...ories SECURITY SYSTEMS Car alarms Bike alarms Mechanical blockers Immobilizers Sensors Accessories OPTIC AND LIGHT Xenon Bixenon Lamps LED Stroboscopes Optic and Headlights Washers Light rain sensors Accessories PARKTRONICS AND MIRRORS Rear parktronics Front parktronics Combined parktronics Rear view mirrors Accessories HEATING AND COOLING Seat heaters Mirrors heaters Screen wipers heaters Engine ...

Page 2: ...Quick Manual v1 6 Dual SIM tracker with RSR232 RS485 interfaces FMB125 Autogoods 130 1 3 0 c o m u a ...

Page 3: ...attery 6 PC Connection Windows 7 How to install USB drivers Windows 7 Configuration Windows 7 Quick SMS configuration 9 Mounting recommendations 10 LED indications 11 Characteristics 11 Basic characteristics 11 Electrical characteristics 14 Safety information 15 Certification and Approvals 16 Warranty 17 Warranty Disclaimer 17 Autogoods 130 1 3 0 c o m u a ...

Page 4: ...3 FMB125 Wiki Know your device Figure 1 FMB125 device view Autogoods 130 1 3 0 c o m u a ...

Page 5: ...through RS232 4 RS232 TX Output for data transmit through RS232 5 DIN 1 Digital input channel 1 6 INPUT 6 TX EXT LVCAN TX 7 GND Ground pin 10 30 V DC 8 DOUT 1 Digital output channel 1 Open collector output Max 0 5 A DC 9 RS485 A Signal A wire for RS485 10 RS485 B Signal B wire for RS485 11 1WIRE DATA Data for 1 Wire devices 12 INPUT 5 RX EXT LVCAN RX Figure 2 FMB125 2x6 socket pinout Autogoods 130...

Page 6: ...5 FMB125 Wiki Figure 3 FMB125 Wiring scheme Wiring scheme 1 Automotive relay 1 Autogoods 130 1 3 0 c o m u a ...

Page 7: ...Configurator Make sure that SIM card cut off corner is pointing outward from slot SIM slot 1 is closer to PCB SIM slot 2 is the top one 3 Connect battery as shown to device Position the battery in place where it does not obstruct other components 4 After configuration see PC Connection Windows attach device cover back Figure 7 SIM card insert Figure 6 Battery connection Figure 5 Attaching cover ba...

Page 8: ... window 4 In the following window click Install button Setup will continue installing the driver and eventually the confirmation window will appear Click Finish to complete the setup Configuration Windows At first FMB125 device will have default factory settings set These settings should be changed according to the user s needs Main configuration can be performed via Teltonika Configurator softwar...

Page 9: ...device loads configuration from device 2 Save to device saves configuration to device 3 Load from file loads configuration from file 4 Save to file saves configuration to file 5 Update firmware updates firmware on device 6 Read records reads records from the device 7 Reboot device restarts device 8 Reset configuration sets device configuration to default Most important configurator section is GPRS...

Page 10: ...ccelerometer Ignition will be detected by vehicle power voltage between 13 2 30 V Device makes a record On Moving if one of these events happen 300 seconds passes Vehicle turns 10 degrees Vehicle drives 100 meters Speed difference between last coordinate and current position is greater than 10 km h Device makes a record On Stop if 1 hour passes while vehicle is stationary and ignition is off Recor...

Page 11: ...del this may happen in 5 to 30 minutes period When the module is connected measure the voltage again to make sure it did not decrease It is recommended to connect to the main power cable in the fuse box 3 A 125 V external fuse shall be used Connecting ignition wire Be sure to check if it is a real ignition wire i e power does not disappear after starting the engine Check if this is not an ACC wire...

Page 12: ... two seconds Sleep mode Blinking fast for a short time Modem activity Off Device is not working or Device is in boot mode Characteristics Basic characteristics Table 5 Basic characteristics MODULE Name Teltonika TM2500 Technology GSM GPRS GNSS BLUETOOTH GNSS GNSS GPS GLONASS GALILEO BEIDOU SBAS QZSS DGPS AGPS Receiver 33 channel Tracking sensitivity 165 dBM Accuracy 3 m Hot start 1 s Warm start 25...

Page 13: ...igital Inputs 1 Digital Outputs 1 Analog Inputs 1 CAN Adapter inputs 1 1 Wire 1 RS232 1 RS485 1 GNSS antenna External MMCX connector GSM antenna Internal High Gain USB 2 0 Micro USB LED indication 2 status LED lights SIM Dual SIM Memory 128MB internal flash memory PHYSICAL SPECIFICATION Dimensions 65 x 56 6 x 20 6 mm L x W x H Weight 52 g OPERATING ENVIRONMENT Operating temperature without battery...

Page 14: ...ion and firmware update FOTA Web FOTA Teltonika Configurator USB Bluetooth FMBT mobile application Configuration SMS Configuration Events DOUT control Debug GPRS commands Configuration DOUT control Debug Time Synchronization GPS NITZ NTP Fuel monitoring LLS Analog LV CAN200 ALL CAN300 OBDII dongle RS232 RS485 fuel sensor CAN CONTROL Ignition detection Digital Input 1 Accelerometer External Power V...

Page 15: ...Voltage threshold DIN1 7 5 V ANALOG INPUT Input voltage Recommended Operating Conditions Range 1 0 10 V Input resistance Range 1 38 45 kΩ Measurement error on 12V Range 1 0 9 Additional error on 12 V Range 1 108 mV Measurement error on 30 V Range 1 0 33 Additional error on 30 V Range 1 88 mV Input Voltage Recommended Operating Conditions Range 2 0 30 V Input resistance Range 2 150 kΩ Measurement e...

Page 16: ...naccessible to the operator All related devices must meet the requirements of EN 62368 1 standard The device FMB125 is not designed as a navigational device for boats Do not disassemble the device If the device is damaged the power supply cables are not isolated or the isolation is damaged DO NOT touch the device before unplugging the power supply All wireless data transferring devices produce int...

Page 17: ...mixed with general household waste Hereby Teltonika declare under our sole responsibility that the above described product is in conformity with the relevant Community harmonization European Directive 2014 53 EU RED 00647 20 08591 Para maiores informações consulte o site da ANATEL www anatel gov br Este equipamento não tem direito à proteção contra interferência prejudicial e não pode causar inter...

Page 18: ...ed with an equivalent repaired product fulfilling the same functionality TELTONIKA can also repair products that are out of warranty at an agreed cost Warranty Disclaimer TELTONIKA PRODUCTS ARE INTENDED TO BE USED BY PERSONS WITH TRAINING AND EXPERIENCE ANY OTHER USE RENDERS THE LIMITED WARRANTIES EXPRESSED HEREIN AND ALL IMPLIED WARRANTIES NULL AND VOID AND SAME ARE HEREBY EXCLUDED ALSO EXCLUDED ...

Reviews: