21 

 

“Firmware upgrade”: 

it is for camera program upgrade, currently only for ISP part update. How to update: 

As following picture, click “clicking to upload file” icon, open dialog box, select to open the file, and click “upgrade” to start. 

DO NOT power off or do other operation when upgrading, reboot the camera after 5 min when upgrade finished. 

Then login web end to select “reset all” to reset the camera completely. 

 

 

 

 

 

 

 

 

 

 

 

 

Reset to default

 : reset the camera to default setting 

                  Reset simply: reset camera image parameter 

                  Reset Completelyall: reset camera Ethernet and image parameter, language and protocol will not be reset. 

                  Reboot: Reboot ISP part of camera 

 

 

 

 

 

 

1

         

2

         

3

 

Summary of Contents for TLC-600-IP-5-4K

Page 1: ...4K Ultra HD Zoom Camera User Manual Version V1 0 English...

Page 2: ...1...

Page 3: ...2 PACKING LIST 4 QUICK START 4 PRODUCT HIGHLIGHTS 4 CAMERA SPEC 5 CAMERA INTERFACE 6 CAMERA DIMENSION 6 IR REMOTE 7 VISCA PROTOCOL 9 OSD MENU 15 SET IP ADDRESS VIA OSD MENU 17 WEB SETTING 18 VIEW RTSP...

Page 4: ...sportation storage and installation 7 Do not detect the camera housing and cover For any service please contact authorized technicians 8 Video cable and control cable should be individually shielded a...

Page 5: ...o get video control and power supply Fast video format switch less than 3 seconds Special Focusing Algorithm fast and precise focusing performance when zooming Supported field upgrade for firmware Sup...

Page 6: ...0 3m Tele 1 5m Preset No Remote controller 10 RS232 128 only save optical zoom and focus position Control Port RS232 RJ45 Video Port RJ45 SDI Network Port Speed 1000M Noise Reduction 2D 3D S N Ratio...

Page 7: ...15fps 30fps Supported Protocol TCP IP HTTP RTSP RTMP Onvif DHCP VISCA VISCA over IP POE Supported Input Voltage DC12V POE IEEE802 3af Dimension L x W x H 168 8 x 80 x 80 MM Net Weight 0 65KG CAMERA I...

Page 8: ...that was set Green button Codec power button need to learn the button coding Blue button TV power button need to learn the button coding Focus Left Manual focus only valid under manual focus model Zoo...

Page 9: ...eed to be learned Press the Home 0 buttons simultaneously to exit and save all remote data If the button learning fails the camera will enter normal working mode after 15seconds LED will extinguish 3...

Page 10: ...07 00 FF Tele Standard 8x 01 04 07 02 FF Wide Standard 8x 01 04 07 03 FF Tele Variable 8x 01 04 07 2p FF p 0 low 7 high Wide Variable 8x 01 04 07 3p FF Direct 8x 01 04 47 0p 0q 0r 0s FF pqrs Zoom Posi...

Page 11: ...FF Indoor 8x 01 04 35 01 FF Outdoor 8x 01 04 35 02 FF OnePush 8x 01 04 35 03 FF ATW 8x 01 04 35 04 FF Manual 8x 01 04 35 05 FF Sodium lamp 8x 01 04 35 08 FF fluorescent 8x 01 04 35 09 FF OnePush Trigg...

Page 12: ...AM_WDR On 8x 01 04 3D 02 FF Exposure Compensation ON OFF Off 8x 01 04 3D 03 FF Direct 8x 01 04 D3 pq FF pq ExpComp Position 0 0x6 CAM_BackLight BL C On 8x 01 04 33 02 FF BackLight On Off 8x 01 04 33 0...

Page 13: ...FF DHCP off DHCP on 8x 01 04 AE 01 FF DHCP on IP address control IP set 8x 01 04 AB 0p 0q 0r 0s 0m 0n 0x 0y FF Set ip to pq rs mn xy Mask set 8x 01 04 AC 0p 0q 0r 0s 0m 0n 0x 0y FF Set mask to pq rs...

Page 14: ...50 00 FF Auto y0 50 01 FF Indoor mode y0 50 02 FF Outdoor mode y0 50 03 FF OnePush mode y0 50 04 FF ATW y0 50 05 FF Manual CAM_RGainInq 8x 09 04 43 FF y0 50 00 00 0p 0q FF pq R Gain CAM_BGainInq 8x 0...

Page 15: ...FF pqrsmnxy bitrate 1024 20480 MainFrameRateInq 8x 09 04 C2 03 FF y0 50 pp FF frame rate 0xpp 15 30 MainIDRInq 8x 09 04 C2 04 FF y0 50 pp FF IDR Setting 0xpp 5 120 SubstreamResolutionInq 8x 09 04 C3...

Page 16: ...PELCO P PELCO D Default VISCA ADDRESS VISCA 1 7 PELCO P D 1 255 Default 1 BAUD RATE Optional item 2400 4800 9600 115200 Default 9600 RETURN Return to previous menu FOCUS FOCUS MODE AUTO MANUAL PUSH D...

Page 17: ...OFF 3D NR 3D noise reduction OFF AUTO 0 4 the bigger value the less motion noise on image high value will cause image smear Default AUTO SHARPNESS Sharpness setting 0 15 the higher value the higher sh...

Page 18: ...T IP ADDRESS IN MENU 1 Press menu button for 3 seconds enter IP setting menu 2 Using up down navigation key to select parameter needed to set IP Mask Gateway ect can be set 3 Short press Home key to s...

Page 19: ...Features Control Panel 2 Login Run browser input IP address defaulted IP address is 192 168 1 188 to enter login interface can select Language Chinese or English input admin and password to login as...

Page 20: ...rameter Setting Click Setting to enter into parameter setting interafeace as following Video Encode can set image encode mode main stream and sub stream resolution bit rate frame rate bit rate control...

Page 21: ...st saturation Noise reduction includes 2D 3D reduction There is on off option for 2D and off auto 1 4 six options Ethernet includes DHCP mode IP address subnet mask default gateway http port web port...

Page 22: ...start DO NOT power off or do other operation when upgrading reboot the camera after 5 min when upgrade finished Then login web end to select reset all to reset the camera completely Reset to default...

Page 23: ...RTSP VIDEO VIA VLC Default RTSP main streaming address rtsp 192 168 1 188 stream main Default RTSP sub streaming address rtsp 192 168 1 188 stream sub Default RTMP main streaming address rtmp 192 168...

Page 24: ...nsmission control depend on applied program Applied range in the same segment not suitable for bridge network Turn on camera In the menu set VISCA option to OVER IP How to use VISCA over IP VISCA Comm...

Page 25: ...ommand 0x02 0x00 Stores the control command Control reply 0x02 0x01 Stores the reply for the control command Payload length Valid data length in Payload 1 16 is command length For example when valid d...

Page 26: ...able it is necessary to confirm delivery and resent in application Generally when controller sends a command to peripheral equipment controller will wait for the return message then send the next comm...

Page 27: ...t IP address subnet mask gateway parameter in VISCA over IP command otherwise it will cause network breaks off Due to change these parameter network will be in off status Sequence chart when command l...

Page 28: ...27...

Reviews: