Automatically sent SMS alarms (once the GSM remote control mode has
been previously selected)
♦
First equipment turning on (or turning on after the GSM battery has been recharged)
♦
“-3dB forward power” alarm
♦
temperature over 75 °C: “threshold” alarm
♦
“modulation off” alarm (only available if the AGC module is present)
♦
“no power to RF module” alarm
♦
“mains power off” (AC < 160V) and “equipment turning off” alarm
♦
“mains power on” after an off alarm (AC >160V) and correct equipment restarting
The transmitters can send the SMS alarms to two phone numbers as maximum, once they
have been memory pre-set
Find hereunder some SMS alarm examples. In this case the TRANSMITTER NAME is
7a2200, the SERIAL NUMBER is 0018 and the TRANSMITTER SITE is MILANO:
Alarm
Alarm SMS text sent by the transmitter
First equipment turning on
MILANO POWER-UP FROM 7a2200 SN 0018
“-3dB forward power” alarm
MILANO ALARM: 7a2200 SN 0018 –3dB F.PWR
Temperature over 75 °C: “threshold”
MILANO ALARM: 7a2200 SN 0018 TEMP. >75C
“modulation off” alarm
MILANO ALARM: 7a2200 SN 0018 MOD. OFF
“no power to RF module” alarm
MILANO ALARM: 7a2200 SN 0018 PWR SUPPLY
“mains power off”
MILANO ALARM: 7a2200 SN 0018 AC FAULT
“mains power on” after an off alarm
MILANO ALARM: 7a2200 SN 0018 AC OK
SMS commands text protocol
The SMS command text has to be sent as follows:
TRANSMITTER NAME, SERIAL NUMBER, COMMAND
Type all the words in the text using small characters, do not leave any blank space within
them but use a comma instead. If the SMS command text is not correct, the transmitters
will neither start any operation nor reply any SMS message to the owner / technician. The
character // states the end of the SMS message.
Find hereunder some SMS command examples. In these examples the TRANSMITTER
NAME is 7a2200, the SERIAL NUMBER is 0018 and the TRANSMITTER SITE is
MILANO:
SMS Command
SMS Command text to be sent to the transmitter
TRANSMITTER WORKING CONDITIONS 7a2200,0018,status
TRANSMITTER POWER ON 7a2200,0018,start
TRANSMITTER POWER OFF
7a2200,0018,stop
ALARMS RESET
7a2200,0018,reset
FORWARD POWER SETTING 7a2200,0018,pwr=02100
The forward power value to set has always to be typed using 5 figures
(for instance: to set a 200W forward power it’s necessary to type 00200).
The transmitter serial number has always to be typed using 4 figures.
Summary of Contents for A07A2200S
Page 24: ...A07A2200S 380 221 R02 Pag 24 ...
Page 51: ...A07A2200S 380 221 R02 Fig 9 a ...
Page 54: ...A07A2200S 380 221 R02 23 REMOTE 24 AC MAINS INPUT ...
Page 85: ...DT50 100 manual 380 209 R00 Pag 77 AUDIOIN BOARD AUDIO INPUTS ...
Page 86: ...DT50 100 manual 380 209 R00 Pag 78 AUDIOIN BOARD AUDIO INPUTS ...
Page 87: ...DT50 100 manual 380 209 R00 Pag 79 AUDIOIN BOARD AUDIO INPUTS ...
Page 91: ...DT50 100 manual 380 209 R00 Pag 83 DLCD BOARD DISPLAY DRIVER ...
Page 92: ...DT50 100 manual 380 209 R00 Pag 84 DLCD BOARD DISPLAY DRIVER ...
Page 96: ...DT50 100 manual 380 209 R00 Pag 88 MBA BOARD MOTHER BOARD ...
Page 97: ...DT50 100 manual 380 209 R00 Pag 89 MBA BOARD MOTHER BOARD ...
Page 98: ...DT50 100 manual 380 209 R00 Pag 90 MBA BOARD MOTHER BOARD ...
Page 99: ...DT50 100 manual 380 209 R00 Pag 91 MBA BOARD MOTHER BOARD ...
Page 103: ...DT50 100 manual 380 209 R00 Pag 95 SINTD BOARD VCO OSCILLATOR ...
Page 104: ...DT50 100 manual 380 209 R00 Pag 96 SINTD BOARD VCO OSCILLATOR ...
Page 107: ...DT50 100 manual 174 1 74HC08D Gate 2 Input AND U1 DMPX BOARD STEREOCODER 380 209 R00 Pag 99 ...
Page 108: ...DT50 100 manual 380 209 R00 Pag 100 DMPX BOARD STEREOCODER ...
Page 109: ...DT50 100 manual 380 209 R00 Pag 101 DMPX BOARD STEREOCODER ...
Page 112: ...DT50 100 manual 380 209 R00 Pag 104 AGC BOARD AUDIO AUTOMATIC GAIN CONTROL ...
Page 113: ...DT50 100 manual 380 209 R00 Pag 105 AGC BOARD AUDIO AUTOMATIC GAIN CONTROL ...