AZ3s USER MANUAL
ST.TEC.054
23 / 60
4.1.
Drive data
The drive data must be configured in order to avoid malfunctions or failures.
4.1.1.
PARAMETERS
Variable
Type
Code
Unit
Default
Range
Can open
address
Modbus logical
address
V bus max*
FLOAT
DD1
V
60
0÷100
INDEX
SUB
203Dh
HR
60
61
Nominal current rms*
FLOAT
IC1
A
30
-100÷100
INDEX
SUB
203Eh
HR
68
69
Alimentation power*
FLOAT
AD1
W
3.36
0÷1.0E6
INDEX
SUB
2053h
02h
HR
318
319
*These parameters once changed, must be saved. The new value assigned to this parameter will become operational only
after a power reset.
4.1.2.
C
ONFIGURATIONS
Nominal current rms is the nominal current of the drive, Alimentation power is the power absorbed
by the drive with power stage disabled and V bus max is the maximum input voltage. It is
recommended to maintain the default values for Nominal current rms and V bus max, only
Alimentation power must be changed because in function of the encoder the power absorption of
the drive changes.