AZ3s USER MANUAL
ST.TEC.054
25 / 60
AZ3s can handle incremental encoder with Hall, with every displacement between U phase rising
edge and zero mark. The displacement is configurable through Encoder phase displacement, for
example if zero mark is positioned exactly on U phase rising edge, then Encoder phase displacement
must be set to zero. In the following image is possible to understand how setting Encoder phase
displacement in order to obtain the desired displacement.
EXAMPLE: if a motor has an incremental encoder with Hall with a displacement between U phase
rising edge and zero mark of 180° (3.14 rad), it is sufficient to set Encoder phase displacement to 3.14.
AZ3s can perform an auto-phasing routine for motors with incremental encoder with Hall.
Prior to start with the auto-phasing routines, disconnect the motor from the load and if a brake is
connected to the motor, disengage it with directs control as described in chapter 4.7. Factor
parameters must be set properly before starting with auto-phasing routine.
In order to start the auto-phasing routines set to 1 Phasing in progress and wait until Phasing in
progress become zero. After auto-phasing procedure is ended, save all the parameters and restarts
the drive. At drive restart check that auto-phased motor is set to 1.