AZ3s USER MANUAL
ST.TEC.054
28 / 60
Velocity factor numerator and Velocity factor denominator are used in order to match the
velocity unit to the user-defined velocity unit.
𝑉𝑒𝑙𝑜𝑐𝑖𝑡𝑦 𝑣𝑎𝑙𝑢𝑒 =
𝑉𝑒𝑙𝑜𝑐𝑖𝑡𝑦 𝑖𝑛𝑡𝑒𝑟𝑛𝑎𝑙 𝑣𝑎𝑙𝑢𝑒 ∗ 𝑓𝑒𝑒𝑑 𝑐𝑜𝑛𝑠𝑡𝑎𝑛𝑡
𝑉𝑒𝑙𝑜𝑐𝑖𝑡𝑦 𝑒𝑛𝑐𝑜𝑑𝑒𝑟 𝑟𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛 ∗ 𝑔𝑒𝑎𝑟 𝑟𝑎𝑡𝑖𝑜
∗
𝑉𝑒𝑙𝑜𝑐𝑖𝑡𝑦 𝑓𝑎𝑐𝑡𝑜𝑟 𝑛𝑢𝑚𝑒𝑟𝑎𝑡𝑜𝑟
𝑉𝑒𝑙𝑜𝑐𝑖𝑡𝑦 𝑓𝑎𝑐𝑡𝑜𝑟 𝑑𝑒𝑛𝑜𝑚𝑖𝑛𝑎𝑡𝑜𝑟
EXAMPLE: if the user want to use rpm instead of rps, Velocity factor numerator must be set to
60 and Velocity factor denominator must be set to 1.
If different units of measure between position measurement and velocity measurement are needed,
the advice is to set before feed constant for reach the desired position unit of measure and then with
Velocity factor numerator and Velocity factor denominator adjust velocity
unit of measure
.
𝑃𝑜𝑠𝑖𝑡𝑖𝑜𝑛 𝑣𝑎𝑙𝑢𝑒 =
𝑃𝑜𝑠𝑖𝑡𝑖𝑜𝑛 𝑖𝑛𝑡𝑒𝑟𝑛𝑎𝑙 𝑣𝑎𝑙𝑢𝑒 ∗ 𝑓𝑒𝑒𝑑 𝑐𝑜𝑛𝑠𝑡𝑎𝑛𝑡
𝑃𝑜𝑠𝑖𝑡𝑖𝑜𝑛 𝑒𝑛𝑐𝑜𝑑𝑒𝑟 𝑟𝑒𝑠𝑜𝑙𝑢𝑡𝑖𝑜𝑛 ∗ 𝑔𝑒𝑎𝑟 𝑟𝑎𝑡𝑖𝑜