AZ3s USER MANUAL
ST.TEC.054
36 / 60
4.8.
Start-up option
With AZ3s it is possible to configure which status of the DS402 reach at the power on of the device.
4.8.1.
P
ARAMETERS
Variable
Type
Code
Unit
Default
Range
Can open
address
Modbus logical
address
Ready to switch on is
reached at start up
COIL
DRF2
-
0
-
INDEX
SUB
2019h
(bit 1)
COIL
18
Operation enabled is
reached at start up
COIL
DRF3
-
0
-
INDEX
SUB
2019h
(bit 2)
COIL
19
4.8.2.
C
ONFIGURATION
At the start-up of AZ3s, when power is provided to the drive, three possible DS402 states (refer to
chapter 5.4) can be reached in function of the state of Ready to switch on is reached at start up and
Operation enabled is reached at start up.
If no one of this flags are set to 1, then at the start up the drive reaches the DS402 state “Switch on
disabled”.
When Ready to switch on is reached at start up is set to 1, then the drive reach the DS402 state
“Ready to switch on”, when instead Operation enabled is reached at start up is set to 1 (or when this
two flags are both set to 1), the drive reach the DS402 state “Operation enabled”.