AZ3s USER MANUAL
ST.TEC.054
54 / 60
6.3.
Coils
Variable
Type
Code
Unit
Default
Range
Can open
address
Modbus logical
address
Phasing in progress
COIL
DF1
-
0
-
INDEX
SUB
2018h
(bit 0)
COIL
1
Start phasing
COIL
DF2
-
0
-
INDEX
SUB
2018h
(bit 1)
COIL
2
Invert Position
feedback
COIL
DF5
-
0
-
INDEX
SUB
2018h
(bit 4)
COIL
5
auto-phased motor
COIL
DF6
-
0
-
INDEX
SUB
2018h
(bit 5)
COIL
6
Invert speed feedback
COIL
DF7
-
0
-
INDEX
SUB
2018h
(bit 6)
COIL
7
TDI CW manage enable
COIL
DRF1
-
0
-
INDEX
SUB
2019h
(bit 0)
COIL
17
Ready to switch on is
reached at start up
COIL
DRF2
-
0
-
INDEX
SUB
2019h
(bit 1)
COIL
18
Operation enabled is
reached at start up
COIL
DRF3
-
0
-
INDEX
SUB
2019h
(bit 2)
COIL
19
Brake activation
COIL
DRF8
-
0
-
INDEX
SUB
2019h
(bit 7)
COIL
24
Brake value
COIL
DRF9
-
0
-
INDEX
SUB
2019h
(bit 8)
COIL
25
EEPROM autophasing
data cleaning
COIL
DRF11
-
0
-
INDEX
SUB
2019h
(bit 10)
COIL
27
EEPROM parameters
cleaning
COIL
DRF12
-
0
-
INDEX
SUB
2019h
(bit 11)
COIL
28
EEPROM total cleaning
COIL
DRF13
-
0
-
INDEX
SUB
2019h
(bit 12)
COIL
29
START
COIL
BKS1
-
0
-
INDEX
SUB
201Bh
(bit 0)
COIL
81
NOT READY TO SWITCH
ON
COIL
BKS2
-
0
-
INDEX
SUB
201Bh
(bit 1)
COIL
82
SWITCH ON DISABLED
COIL
BKS3
-
0
-
INDEX
SUB
201Bh
(bit 2)
COIL
82
READY TO SWITCH ON
COIL
BKS4
-
0
-
INDEX
SUB
201Bh
(bit 3)
COIL
83
SWITCHED ON
COIL
BKS5
-
0
-
INDEX
SUB
201Bh
(bit 4)
COIL
84
OPERATION ENABLED
COIL
BKS6
-
1
-
INDEX
SUB
201Bh
(bit 5)
COIL
85
QUICK STOP ACTIVE
COIL
BKS7
-
0
-
INDEX
SUB
201Bh
(bit 6)
COIL
86
FAULT
COIL
BKS8
-
0
-
INDEX
SUB
201Bh
(bit 7)
COIL
87
FAULT REACTION
ACTIVE
COIL
BKS9
-
0
-
INDEX
SUB
201Bh
(bit 8)
COIL
88