background image

Page 6

           = 1 Delay on Energise (On Delay)

The timer starts counting when the 

Start

 signal is activated.  At the end of the time 

period         , the output relay 

OUT1

 energises and remains energised until the 

Reset

 signal 

is activated.

Reset

      

= 4 Monostable Reset-Start/Stop

Activating the 

CNT

 input and keeping it active, resets and starts the timer counting and the 

count then stops on the value reached when the 

CNT

 input is deactivated (disabling the 

output if this was activated).  This count operation mode is similar to a traditional timer in 
which the counting is enabled when the timer is powered and the 

Reset

 occurs when the 

power supply is removed.  In this mode the       

Start/Stop

 key (if            is different to 

oF

only acts as a 

Reset

.

RESET

Count

CNT

Reset/

Start

Stop

0  1  2  3

0  1  2  3

      

= 5 Bistable Reset-Start/Stop

Activating the 

CNT

 input 

Resets

 the timer.  Activating the 

CNT

 input again starts the timer 

counting and activating the 

CNT

 input for a third time stops the count on the value reached 

(disabling the output if this was activated).  In this mode the       

Start/Stop

 key (if            = 

2

) acts exactly the same way as the 

CNT

 input.

RESET

Count

CNT

Stop

0  1  2  3  0

0  1  2  3  4  0

      

= 6 Bistable Start/Stop-Reset

Activating the 

CNT

 input starts the timer counting and the 

CNT

 input can then be 

deactivated.  Activating the 

CNT

 input again, if done before the end of the count, stops 

the count (disabling the output if this was activated) and 

Resets

 the count.  If the second 

CNT

 impulse arrives after the end of the count, a new count cycle is started.  In this mode 

the       

Start/Stop

 key (if            = 

2

) at the end of         time acts exactly the same way as 

the 

CNT

 input.

Stop/ 

Reset

Start

Reset

0

Reset/

Start

Stop

0

0

Reset Start

Reset

RESET

Count

CNT

0  1  2  0

0  1  2  3  0

Start

Start

0  1  2  0

Start

Stop/ 

Reset

End/ 

Reset

Stop/ 

Reset

OUT1 OPERATING MODES

Start

OUT1

           = 2 Interval

The timer starts counting and the output relay 

OUT1

 energises when the 

Start

 signal is 

activated.  At the end of the time period         , the output relay 

OUT1

 de-energises.  The 

output can only be reactivated after a 

Reset

 signal and a new 

Start

 signal.

Reset

Start

OUT1

           = 3 Immediate Cycle with Variable On and Off Times

The timer starts counting and the output relay 

OUT1

 energises when the 

Start

 signal is 

activated.  At the end of the time period         , the output relay 

OUT1

 de-energises and 

then after time period         

OUT1

 energises again and this repeats indefinitely until the 

Stop/Reset

 signal is activated.

Reset

Start

OUT1

           = 4 Delayed Cycle with Variable On and Off Times

The timer starts counting when the 

Start

 signal is activated.  At the end of the time period           

.        the output relay 

OUT1

 energises and then after time period         

OUT1

 de-energises.  

After a further time period         

OUT1

 energises again and this repeats indefinitely until the 

Stop/Reset

 signal is activated.

Reset

Start

OUT1

           = 5 Single Delayed Cycle with Variable On and Off Times

The timer starts counting when the 

Start

 signal is activated.  At the end of the time period           

.        the output relay 

OUT1

 energises and then after time period         

OUT1

 de-energises.  

The cycle can only be reactivated after a 

Reset

 signal and a new 

Start

 signal.

Reset

Start

OUT1

      

= 3 Monostable Start/Stop

Activating the 

CNT

 input and keeping it active, starts the timer counting and the count then 

stops on the value reached when the 

CNT

 input is deactivated (without disabling the output 

if this was activated).  The next 

CNT

 impulse resumes the count from the point it stopped, 

and so on, until the 

Reset 

signal.  In this mode the       

Start/Stop

 key (if            is different 

to 

oF

) only acts as a 

Reset

.

RESET

Count

CNT

Start

Stop

Start

Reset

0  1  2  3

4  5  6  7

0

Stop

Summary of Contents for TT33

Page 1: ...TT33 Digital Multifunction Timer User Manual Tempatron Eltime House Hall Road Maldon Essex CM9 4NF UK Telephone 44 0 1621 859500 Email sales tempatron co uk Web www tempatron co uk...

Page 2: ...corrosive or flammable gases could be present ELECTRICAL Power Supply Voltage 24Vac dc or 100 240Vac Power Consumption Burden 3VA Frequency 50 60Hz Wiring 2mm screw type terminals Data Retention EEPRO...

Page 3: ...When in programming mode press to increase the setting value and to select parameters In programming mode press together with the key to change the programming level of the parameters Press together...

Page 4: ...can be set within the limits established by parameters and and can be set within the limits estblished by and Page 4 SET TIME PROGRAMMING FAST MODE PARAMETER SETTING MODE To access the timer function...

Page 5: ...is requested Enter the value and press the key to confirm The display shows for 2 seconds and then all parameters have been reset to the factory default values It is possible to completely lock the ti...

Page 6: ...nt CNT 0 1 2 0 0 1 2 3 0 Start Start 0 1 2 0 Start Stop Reset End Reset Stop Reset OUT1 OPERATING MODES Start OUT1 2 Interval The timer starts counting and the output relay OUT1 energises when the Sta...

Page 7: ...OUT2 5 Start OUT1 Reset OUT2 4 4 OUT2 Operates the same function as OUT1 but in advance by time OUT2 operates exactly the same function as OUT1 but OUT2 operates in advance of OUT1 has the same time r...

Page 8: ...STOP 5 Bistable RESET START STOP 6 Bistable START STOP RESET 2 11 OUT1 output operating mode 1 Delay on Energise On Delay 2 Interval 3 Immediate Cycle with Variable On and Off Times 4 Delayed Cycle w...

Reviews: