OPERATION WITH A POWER SUPPLY INTERRUPTION

When the power supply to the timer is restored after an interruption the timing count can be programmed using the           parameter to operate as follows:

1  

The timing count resets.

2  

The timing count stops at the value reached when the power supply ceased.  The timing count continues once a new 

Start

 signal is activated.

3  

The timing count stops at the value reached when the power supply ceased.  When the power supply is restored the count restarts from that value if  

    the conditions for restarting are present (e.g. the timer was counting within a bistable mode when the power supply ceased).

Parameter

Description

Range

Default

Note

1

          Minimum set time

0 to S.Ht1

0

2

          Maximum set time

S.Lt1 to 9999

99.59

3

          Minimum set time

0 to S.Ht2

0.00

4

          Maximum set time

S.Lt2 to 9999

99.59

5

          Time range

1  hours (9999h) 
2  hours & minutes (99h 59min) 
3  minutes & seconds (99min 59s)
4  seconds (99.99s)

3

6

          Time range

1  hours (9999h) 
2  hours & minutes (99h59min) 
3  minutes & seconds (99min59s)
4  seconds (99.99s)

3

7

          Set time

S.Lt1 to S.Ht1

1.00

8

          Set time

S.Lt2 to S.Ht2

0.00

9

          Set time

S.Lt1 to S.Ht1

0.00

10

CNT input operating mode

1  Bistable START/STOP 
2  Bistable RESET-START/STOP
3  Monostable START/STOP 
4  Monostable RESET-START/STOP
5  Bistable RESET/START/STOP 
6  Bistable START/STOP-RESET

2

11

OUT1 output operating mode

1  Delay on Energise (On Delay)
2  Interval
3  Immediate Cycle with Variable On and Off Times
4  Delayed Cycle with Variable On and Off Times
5  Single Delayed Cycle with Variable On and Off Times

1

12

OUT2 output operating mode

oF OUT2 disabled
1  OUT2 operates exactly the same as OUT1
2  Instantaneous contact
3  OUT2 operates the same function as OUT1 but with           time
4  OUT2 operates the same function as OUT1 but in advance by           time
5  OUT2 energises when the buzzer sounds

oF

13

Count mode

uP  Up
dn  Down

uP

14

Buzzer operating mode

oF Disabled
1  The internal buzzer activates at the end of           for           period and when  
    keys are pressed
2  The internal buzzer activates at the end of           for           period
3  The internal buzzer only activates when keys are pressed
4  Only the external buzzer activates only at the end of           for           period  
    (if OUT2 configured with              = 5). 

1

15

        -START/STOP key operating mode

oF  No function
1   RESET only
2   RESET-START/STOP if             = 1/2 or RESET/START/STOP if            = 5/6

2

16

Set times visible with fast set time procedure 
(         key)

oF  No set time visibility
1
2
3              and
4          
5              and
6              and
7              ,           and
8              only directly with the                  keys with no         key pressed

1

17

Backup operation mode

1  The timing count resets
2  The timing count stops at the value reached when the power supply ceased
3  The timing count stops at the value reached when the power supply ceased  
    and restarts from that value if the conditions for restarting are present

1

18

Key lock

oF  Key lock disabled
1 to 9999s (value in seconds of key inactivity after which the keys are locked)

oF

19

Passcode for parameters protection

oF  Passcode disabled
1 to 9999

oF

PROGRAMMABLE PARAMETERS

Summary of Contents for TT33

Page 1: ...TT33 Digital Multifunction Timer User Manual Tempatron Eltime House Hall Road Maldon Essex CM9 4NF UK Telephone 44 0 1621 859500 Email sales tempatron co uk Web www tempatron co uk...

Page 2: ...corrosive or flammable gases could be present ELECTRICAL Power Supply Voltage 24Vac dc or 100 240Vac Power Consumption Burden 3VA Frequency 50 60Hz Wiring 2mm screw type terminals Data Retention EEPRO...

Page 3: ...When in programming mode press to increase the setting value and to select parameters In programming mode press together with the key to change the programming level of the parameters Press together...

Page 4: ...can be set within the limits established by parameters and and can be set within the limits estblished by and Page 4 SET TIME PROGRAMMING FAST MODE PARAMETER SETTING MODE To access the timer function...

Page 5: ...is requested Enter the value and press the key to confirm The display shows for 2 seconds and then all parameters have been reset to the factory default values It is possible to completely lock the ti...

Page 6: ...nt CNT 0 1 2 0 0 1 2 3 0 Start Start 0 1 2 0 Start Stop Reset End Reset Stop Reset OUT1 OPERATING MODES Start OUT1 2 Interval The timer starts counting and the output relay OUT1 energises when the Sta...

Page 7: ...OUT2 5 Start OUT1 Reset OUT2 4 4 OUT2 Operates the same function as OUT1 but in advance by time OUT2 operates exactly the same function as OUT1 but OUT2 operates in advance of OUT1 has the same time r...

Page 8: ...STOP 5 Bistable RESET START STOP 6 Bistable START STOP RESET 2 11 OUT1 output operating mode 1 Delay on Energise On Delay 2 Interval 3 Immediate Cycle with Variable On and Off Times 4 Delayed Cycle w...