1–4 Keys and Displays

KEYPAD OPERATION 

 

SCROLL KEY: 

 

This key is used to select a parameter to be viewed or adjusted. 

 

UP KEY: 

 

This key is used to increase the value of the selected parameter. 

 

DOWN KEY: 

 

This key is used to decrease the value of the selected parameter. 

 

RESET KEY: 

 

This key is used to: 

1. Revert the display to show the process value. 

2. Reset the latching alarm, once the alarm condition is removed. 

3. Stop the manual control mode, auto-tuning mode, and 

calibration mode. 

4. Clear the message of communication error and auto-tuning 

error. 

5. Restart the dwell timer when the dwell timer has timed out. 

6. Enter the manual control menu when in failure mode. 

 

ENTER KEY: 

Press 

 for 5 seconds or longer. 

 Press 

 for 5 seconds to: 

1. Enter setup menu. The display shows 

 . 

2. Enter manual control mode—when manual control mode 

 is selected. 

3. Enter auto-tuning mode—when auto-tuning mode 

 is 

selected. 

4. Perform calibration to a selected parameter during the 

calibration procedure. 

      Press 

 for 6.2 seconds to select manual control mode. 

      Press 

 for 7.4 seconds to select auto-tuning mode. 

      Press 

 for 8.6 seconds to select calibration mode.

R

TEMPCO

Table 1.1  Display Form of Characters

Display program code of the product for 
2.5 seconds. 
The left diagram shows program number 
6 for TEC-9100 with version 12. 
The program no. for TEC-7100 is 13, for 
TEC-8100 is 11 and for TEC-4100 is 12.

Summary of Contents for TEC-9100

Page 1: ... within this console Power to all equipment must be disconnected before installation or beginning any troubleshooting procedures Heater output wiring and component replacement must be made by qualified personnel only 3 To minimize the possibility of fire or shock do not expose this console to rain or excessive moisture 4 Do not use this console in areas where hazardous conditions exist such as exc...

Page 2: ... ABC 1 R Used for TEC 9100 Controller EHD 124 290 for 4 zone units Fuse 1 rated 1 5 Amp 250V x 1 slow acting BUSS ABC 1 5 R Used for TEC 9100 Controller EHD 124 300 for 2 zone units Fuses 2 rated 8 amps 250V x 1 fast acting BUSS ABC 8 R EHD 124 279 for 3 zone units Fuses 3 rated 5A 250V x 1 fast acting BUSS ABC 5 R EHD 124 282 for 4 zone units Fuses 4 rated 4 amps 250V x 1 fast acting BUSS ABC 4 R...

Page 3: ...ow cost enhanced reliability and higher density Fast sampling rate The sampling rate of the input A to D converter is 5 times second The fast sampling rate allows this series to control fast processes Fuzzy control The function of Fuzzy control is to adjust PID parameters from time to time in order to make manipulation of the output value more flexible and adaptive to various processes The result ...

Page 4: ...well timer has timed out 6 Enter the manual control menu when in failure mode ENTER KEY Press for 5 seconds or longer Press for 5 seconds to 1 Enter setup menu The display shows 2 Enter manual control mode when manual control mode is selected 3 Enter auto tuning mode when auto tuning mode is selected 4 Perform calibration to a selected parameter during the calibration procedure Press for 6 2 secon...

Page 5: ...5 1 5 Menu Overview ...

Page 6: ...t shown in the above table NOTE It is strongly recommended that a process should incorporate a LIMIT CONTROL such as the TEC 910 which will shut down the equipment at a preset process condition in order to preclude possible damage to products or system Information in this user s manual is subject to change without notice ...

Page 7: ...en all setup data as well as user data refer to section 1 5 except the set point are locked to prevent them from being changed If ALL is selected for LOCK then all parameters are locked to prevent them from being changed 3 2 Signal Input INPT Selects the sensor type or signal type for signal input Range thermocouple J TC K TC T TC E TC B TC R TC S TC N TC L TC RTD PT DN PT JS Linear 4 20mA 0 20mA ...

Page 8: ...lagged filtered signal if used for control may produce an unstable process The controller will enter failure mode if one of the following conditions occurs 1 SBER occurs due to input sensor break or input current below 1mA if 4 20 mA is selected or input voltage below 0 25V if 1 5V is selected 2 ADER occurs due to the A D converter of the controller failing Output 1 and output 2 will perform the f...

Page 9: ...e mode or manual control mode is entered Procedures Auto tuning can be applied either as the process is warming up cold start or when the process has been in a steady state warm start After the auto tuning procedures are completed the AT indicator will cease to flash and the unit will revert to PID control using its new PID values The PID values obtained are stored in the nonvolatile memory Auto T...

Page 10: ...10 Table A 1 Error Codes and Corrective Actions ...

Page 11: ... compliance with any applicable specification TEC Temperature Controllers are warranted to be free from defects in material and workmanship for two 2 years after delivery to the first purchaser for use Tempco s sole responsibility under this warranty at Tempco s option is limited to replacement or repair free of charge or refund of purchase price within the warranty period specified This warranty ...

Page 12: ...le Heaters Process Heaters Temperature Control Cartridge Heaters Coil Cable Heaters Strip Heaters Tubular Heaters Instrumentation Temperature Sensors HEAT THINGS UP HEAT THINGS UP With Thousands of Design Variations We Make Everything You Need Custom Manufacturer Since 1972 ELECTRIC HEATING ELEMENTS TEMPERATURE CONTROLS SENSORS PROCESS HEATING SYSTEMS Copyright 2020 All Rights Reserved ...

Reviews: