24
Instructions manual |
www.grupotemper.com
KDP6
Wall presence detector
Technical specifications
Rated voltage
230V~ 50Hz
Load
Max.8A(cosφ=1)
lncandescent Lamp: Max. 1840W
HV Halogen Lamp: Max. 1000W
LV Halogen Lamp: Max. 300VA
Fluorescent Lamp: Max. 400VA
(Uncompensated)
lnstallation height 2.0- 3.0M, recommended installation height is
approx. 2.5M
Detection Range
up to 270°
Lux Adjustment
From “
”(approx. 5LUX) to “
“ (∞)
Auto OFF Time
Delay
“Test”, from “-”(approx. 6 sec) to “+”
(approx. 10 min) and “
“
Meter adjustment
Max. 10M
LED mode
OFF / Warning / Watch
Power
Consumption
Approx. 1W
Operating
Temperature
-20ºC to +45ºC
Environmental
Protection
IP44
Installation and assembly of electrical equipment must be carried
out by qualified electricians. Contact a qualified electrician in the
event of fault or break down.