OPERATION MENU’S
6.4.1
Graphic Process Control
Figure 6-27 Graphic Process Control
The Graphic Process Control is a graphical interface to the tube control. The screen contains
three main divisions, the process recipe status in the top field, the tube status in the large
center field and the control buttons on the left.
Any alarm messages will be displayed in the bottom line
The process recipe field shows
•
The tube Id and name
•
The recipe Id and name
•
The message for the current step
•
The action for which the controller is waiting
•
The process time
•
The step number and time
The tube status field gives a graphical overview of the temperature (both spike (eternal) and
paddle (internal) thermocouple signals), boat position, MFC and valve setting and pressure (if
applicable).