INSTALLATION
CAUTION
Lift or pull the wrappings away from all stainless steel
surfaces. Do not drag packing materials across the
equipment surfaces as this may cause damage.
•
Depending what type of packing material is being used; a final de-dusting must be
done before it is put into position. The system has been pre-cleaned before leaving
our factory.
3.3 Installation
CAUTION
During movement, the furnace assembly is slightly
unstable and should be considered top heavy.
3.4 The
furnace
CAUTION
Items, described in this paragraph, are the customer's
responsibility.
•
Check the bottom side of the furnace for levelers and sagged wires.
•
To prevent moving of the furnace during perpendicular lift up, use wooden packing
block.
•
Locate the furnace in its final position.
CAUTION
The tines of the forklift should extend under complete
width of the furnace when moving.
•
Place a spirit-level on top of the furnace. The furnace can then be leveled, by
adjusting the adjustable feet on the bottom of the furnace.
•
Locate the loadstation and the gascabinet in their position.
•
Level and align the loadstation and the gascabinet with respect to the furnace.
•
Install all facilities as indicated on the outline drawing and verify that they comply
with the labeling.
F
URNACE
R
EFERENCE
M
ANUAL
3-2