Product Instructions
2
lightly press the “power” key to confirm, the menu sequence for circulation when press “menu” is shown as
figure 2 :
4.
Programming methods: In normal state, press “menu” key, when flashes, press the “power” key
lightly:
a)
Firstly, into the local time calibration, the user can press “menu” key to select week-hour-minute, using
or
to adjust, pressing “power” key to confirm all the calibration.
b)
After the local time calibration, press the “power” key to get into the time periods for programmable
settings of Monday, the right side will show the time periods which suggests the current time period of
the menu. Press the “menu” key to select the starting time of each time periods---setting temperature,
using
or
to adjust, pressing “power” key to confirm all the settings.
c)
After the programming of Monday, pressing “power” key to get into “Tuesday” programming settings,
selecting the starting time of each time periods of Tuesday as method b), pressing “power” key to
confirm all the settings.
d)
Repeated methods b) and c) to complete the starting time and setting temperatures of 4 time periods a
day and 7 days a week, wait 10 seconds to let the system automatically confirm to the normal state.
4、
Technical data:
5、
Typical product wiring diagram:
Note: "N-O" of the output power relay contact capacity is 16 A, heating after power on, controlled by the protection
temperature.
"T-T" connects 5 K external protection temperature sensors.
Content
Statement
Content
Statement
Power supply
AC220V±10
﹪
50/60HZ
Power consumption
≤
1W
Control range
0
~
99
℃
Temperature elements
NTC,5K
Control precision
±1
℃
Protection temperature sensor
NTC,5K
Outer shell
PC+ABS Anti-flaming
Dimension
86mm *86mm*13mm
Weight
210g
Wiring connection
terminal