background image

The data logger is mainly used to record the temperature of food in storage and transportation. 
It helps accurately monitor the whole process to indicate whether food is safe and fresh.

After the data logger is plugged into a computer USB port, a PDF data report will be 
created automatically. The LCD screen will display report generation progress. When 
created, the report can be viewed. The creation will not last for more than 4 minutes.

USB Port
LCD Screen
Configuration Info Label
Buttons 
Sensor
Barcode Label

Users can reconfigure parameters via the data management software. The reconfiguration will clear the original parameters 
and data 

The logger supports three upper limits and two lower limits

The range that is out of alarm thresholds

The logger records the single time for continuous out-of-limit events

The data logger records the cumulative time of all the out-of-limit events.    

The logger does not alarm immediately when the temperature is within the alarm zone. It begins to alarm 

only when the alarm delay time elapses

Mean kinetic temperature is an evaluation method that indicates the effect of temperature fluctuation on 

stored articles

single/cumulative

USB port

PDF format

single-use 3.6V lithium battery

IP65

Alarm type

Data interface

Report type

Battery

Battery life

Protection grade

internal NTC thermistor

Memory capacity

16000 readings (MAX)

Log interval

10 sec ~24 hr

Alarm threshold

default (customizable)

2 years (stored and used under normal 

temperature environment)

Delayed start

Not started

Readings

Max temperature

Min temperature

Upper limit 3

Upper limit 2

Upper limit 1

Lower limit 1

Lower limit 2

Current time

Timing start 

Start status

MKT value

Average temperature

12

13

14

15

16

PDF creation progress

Sensor fault

Alarmed

Mark

Data clear

USB communicating

Operating Instructions

Description of the menus

Description of the combined indicators and other status

Action

Operation

Start the data logger

Stop the data logger

Show status

Set Mark

Press  and hold  the start button  for  about 5 seconds 

Press  and  hold  the  stop  button  for  about  5 seconds

Press and release the start button

Press  and hold  the  start  button  for  about 5 seconds

Reusable-Use PDF Temperature Data Logger