User Guide
135
Fields on the screen are described below:
Field
Description
LLDP
Enable/ Disable LLDP feature.
Sending
Interval
The interval among each LLDP message (5~32768s).
TTL
Multiplier
TTL value is used to configure neighbor info’s age time on local devices. TTL =
Min (65535, (TTL multiplier × LLDP packet sending time interval)). Through
adjusting TTL multiplier, you can control this device info's age time on the
neighboring device (2~10s).
Sending
Delay
When local configurations change, each LLDP packet will be sent after one
sending delay time (1~8192s and <= sending time interval/4).
Initialization
Delay
To avoid constant port initialization caused by frequent changes of working
mode, you can configure port initialization delay time. When port's working mode
changes, the initialization will be delayed for some time (1~10s).
Port Setup
Click
Device Management -> LLDP -> Port Setup
to enter interface below:
Fields on the screen are described below: